Preparation; Water-Side Maintenance; Descale The Tank - State Water Heaters SCC 40-40 Installation, User And Service Manual

Table of Contents

Advertisement

11.2
11.3
11.3.1
64
8.
Make sure the air pressure differential is correct, refer to Air pressure differential
(see section 8.9.2).
9.
Make sure the gas supply pressure is correct, refer to Gas supply pressure (see
section 8.9.3).
10.
Make sure the CO
value is correct, refer to CO
2

Preparation

Isolate the water heater from the mains (see section 4.3.2) before you start maintenance
tasks.

Water-side maintenance

To do water side maintenance:
Descale the tank (see section 11.3.1)
Clean the condensate drain (see section 11.3.2)

Descale the tank

To descale and clean the tank:
1.
Decommision the water heater (see section 8.10).
2.
Remove the cover plate (5) on the bottom of the front of the tank.
3.
Remove the isolating material to see the cleaning opening.
4.
Loosen the 6 bolts (4).
5.
Remove the cleaning opening cover (3).
6.
Remove the gasket (2).
7.
Inspect the tank and remove the loose scale deposits and contamination:
a.
Remove the scale and contamination by hand.
b.
If necessary use a descaling agent to remove the scale and contamination.
Contact the supplier of your water heater for advice on what descaling agent to
use.
8.
Replace the gasket.
9.
Close the cleaning opening.
Use a torque wrench to tighten the bolts with a maximal torque of 50 Nm to prevent
damage to the tank
10.
Fill the water heater (see section 8.9.1).
Fig. Cleaning opening
value (see section 8.9.4).
2
1. Cleaning opening
2. Gasket
3. Cleaning opening
cover
4. Bolts
5. Cover plate
Installation, Maintenance and Service part

Advertisement

Table of Contents
loading

Table of Contents