8.3
n
n
8.4
8.4.1
40
Installation diagram
Note
This manual only discusses unvented installations.
Fig. Installation diagram
Note
Use this installation diagram when you:
•
install the water connections (see section 8.4)
•
install the condensate drain (see section 8.5)
•
install the gas connection (see section 8.6)
•
fill the water heater (see section 8.9.1)
•
drain the water heater (see section 8.10.2)
Water connections
Cold water connection
Install the cold water connection:
1.
Install an approved stop valve (4), as required by the applicable regulations.
1. Pressure relief valve
(mandatory if the
mains water pressure
is too high)
3. T&P valve
4. Stop valve
(recommended)
5. Non-return valve
6. Circulation pump
(optional)
9. Drain valve
10. Manual gas valve
11. Service stop valve
(recommended)
12. Temperature gauge
(optional)
13. Condensate drain
14. Draw-off points
15. Expansion valve
16. Expansion vessel
A. Cold water supply
B. Hot water outlet
C. Circulation pipe
D. Gas supply
Installation, Maintenance and Service part