Error 131
Error Message Displayed to user
E131
Condition
M2 actuator disconnected.
Cause
Bad cables and connectors
Bad ECB
Bad actuator
Remedy
Any power to actuator? No, check cable and connections / terminals to actuator.
Swap M2 and M3 be connections at ECB: Does problem follow ECB output terminal, actuator or neither?
If problem follows terminal, replace ECB.
If problem follows actuator, replace actuator
If neither it may be intermittent connection.
Replace ECB / actuator as needed.