CYBEX 70T Service Manual page 61

Hide thumbs Also See for 70T:
Table of Contents

Advertisement

Error 60
Error Message Displayed to user
E60
Interface Board Not Detected!
System Comm Init Timeout! Interface Board Not Detected!
Pressing Cancel button will initiate a system reboot.
Condition
SBC never established communication with the Maintenance Interface Board.
Cause
Check connections between main board and Maintenance Interface Board
Bad Maintenance Interface Board
Bad SBC / SOM board
Remedy
NOTE: Only applicable to consoles with Maintenance Interface Board
Reseat cable connections between main board and Maintenance Interface Board, wiggle cables - watch for LED flickers that may
indicate loose connections