Troubleshooting

If you have followed the instructions carefully and your faucet still does not work properly,
take the following corrective steps:
PROBLEM
Leakage under faucet handle
Water does not shut off
completely
Leaking between spray head
and the hose
Hose does not retract
Low flow
CAUSE
Locking nut has come loose or
cartridge needs to be reseated.
Cartridge may need to be
adjusted or replaced.
Spray head may be loose or
washer is not seated correctly
in the hose connection.
Weight may be installed
incorrectly.
Aerator may be clogged
ACTION
Remove button located at top of handle.
Loosen set screw with hex wrench. Remove
handle and unscrew cartridge cover by
hand. Tighten locking nut with an
adjustable wrench.
Remove button located at top of handle.
Loosen set screw with hex wrench. Remove
handle and unscrew cartridge cover by
hand.
Unscrew
locking
adjustable wrench. Remove ceramic disc
cartridge.
Check for cracks, and if O-ring is seated
correctly. Reseat cartridge.
Tighten spray head by hand until snug.
Make sure washer is seated correctly.
Readjust weight on hose.
Unscrew aerator with aerator key. Hold tip
of spray head and turn on water to flush
debris.