Service Menu Items Description - Rheem IKONIC RTGH-S11i Training And Service Manual

Tankless water heaters
Hide thumbs Also See for IKONIC RTGH-S11i:
Table of Contents

Advertisement

IKONIC Tankless Water Heater Service Manual
GENERAL INFORMATION

1.7 SERVICE MENU ITEMS DESCRIPTION

This tankless water heater can set several operations and display all service information of this water heater with the
Liquid Crystal Display (LCD) on the User Interface.
SERVICE
CURRENT ALARMS:
Check and clear the current
alarms
ALARM HISTORY:
Check and clear the previously
observed alarms
SOFTWARE VERSION:
Software version of the user inter-
face on the water heater
HTR. SOFTWARE VERSION:
Software version of PCB on the
water heater
LIFETIME ON HRS:
Total accumulated powered On
hours of the water heater
LIFETIME WATER:
Total accumulated water
consumption (GPM)
THE ITEM TO SET ITEMS
THE ITEMS TO VIEW SERVICE INFORMATION
32
TOTAL PUMP HOURS:
Total accumulated recirculation
pump operation hours
TOTAL PUMP CYCLES:
Total accumulated ON/OFF cycles
of the recirculation pump
LIFETIME GAS:
Total accumulated energy con-
sumption (KBTU)
SUCCESS IGNITION:
Total accumulated successful
ignitions
FAILED IGNITION:
Total accumulated failed ignitions
FLAME FAILURES:
Total accumulated flame failures
after successful detection of
flame
BYPASS RATIO:
Current bypass ratio
MAX INPUT RATE:
Rated input rate for the water
heater
WH model:
Water heater model
MANIFOLD ROTATE:
Set to rotate the master unit in a
manifold system
RESET DEFAULT?:
Factory reset of the setting
SERVICE ALERTS:
Set operation time to trigger T111
service alert
WIFI RESET:
Reset WiFi
Return to
"CURRENT ALARMS"

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents