3.2.2

Positions of the mounting clips

You fasten the devices with the mounting clips from the accessory kit.
All hygienic devices with display diagonals ≥10" have two recesses for a mounting clip at each
required position.
The 7" device with cast aluminum frame has a different frame geometry. Ensure the correct
positioning of the mounting clips for this device.
To achieve degree of protection IP69 for the respective device, the mounting clips must be
fitted at the positions shown below.
Device
MTP700 Unified Comfort Hygienic
The scope of delivery includes two short set
screws.
These are needed if the material at the
mounting cutout is more than 1.5 mm thick.
In this case, use one mounting clip each with
the short set screw at the "bottom left" and
"bottom right" positions marked in red in the
adjacent figure.
MTP1000 Unified Comfort Hygienic
MTP1200 Unified Comfort Hygienic
Unified Comfort Panels Hygienic
Compact Operating Instructions, 04/2023, A5E52219907-AA
Installing and connecting the device
Positions of the mounting clips
3.2 Mounting the device
29