3.2.3

Inserting the mounting seal

Note
Use a new mounting gasket for each installation, because the promised degree of protection
cannot be guaranteed otherwise.
Requirement
• Before mounting, remove all packaging components.
Procedure
1. Place the device face down on a soft surface.
2. Insert the mounting gasket on the back of the stainless steel frame. Make sure that the nubs
of the gasket are facing downward as shown in the example figure below.
3. Carefully press the first nub on one corner of the gasket into the associated hole on the
front.
4. Starting from the corner, successively attach all the remaining nubs into their holes.
Note
Devices with display diagonals 15" and higher
Devices with display diagonals ≥15" have holes at the corners and elongated holes in the
middle edge area. The nubs of the gaskets have been stamped in a similar way.
Thus, you can compensate for possible warping of the gasket between two corners.
5. Check the correct fit of the mounting gasket.
The mounting gasket is inserted correctly when the following conditions are met:
– All nubs are seated in the respective holes.
– The mounting gasket lies fully flat against the back of the stainless steel frame.
– The edge of the mounting gasket is flush with the edge of the stainless steel frame all
Unified Comfort Panels Hygienic
Compact Operating Instructions, 04/2023, A5E52219907-AA
around.
Installing and connecting the device
3.2 Mounting the device