Installing The Cabinet; Preparing The Space; Installing Anti-Tip Brackets - Perlick HB24 Series Installation & Operation Manual

Single door undercounter refrigeration
Table of Contents

Advertisement

Single Door Undercounter Refrigeration Installation & Operation Manual
INSTALLING THE CABINET - SINGLE DOOR UNDERCOUNTER CABINETS

Preparing the Space

If the unit is to be installed
CAUTION
under a countertop, it is
recommended that the countertop be supported
by a structure other than the unit itself to prevent
damage to the unit.
Make sure the floor under the
CAUTION
unit is level with the surrounding
finished floor. Protect a finished floor with plywood,
cardboard, or some other suitable material before
moving the unit into place. Failure to do this may
result in damage to the floor.
1). Make sure the space opening is correctly sized for
the unit. See chart below for finished rough opening
requirements.
HC24 24" C-Series
Height*
32-1/8" minimum
* NOTE: Separately sold leg and caster kit heights should be
factored into height if required.
HB24 24" ADA-Compliant Series
Height*
32-1/8" minimum
* NOTE: Separately sold leg and caster kit heights should be
factored into height if required.
HD24 18" Shallow-Depth Series
Height*
32-1/8" minimum
* NOTE: No accessory leg or caster kits are available for the
HD24 products.
NOTE: For a cabinet door to open properly, the door must open
a minimum of 90°. Use a minimum 3" filler in corner installations
to assure a full 90° opening. Allow 25" clearance in front of unit
for full door swing and shelf/drawer pull out for all units.
2). Check that the following are level and square:
► Front and interior opening
► Installation opening and floor surface
► Countertop bottom and front edge (if applicable)
CAUTION
NOTE: The floor under the unit
must be at the same level as the surrounding finished
floor. To prevent possible damage to the countertop
do not place heavy objects on countertop directly
over unit.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Depth
Width
24"
24"
Depth
Width
24"
24"
Depth
Width
18"
24"

Installing Anti-Tip Brackets

Unit may tip forward if loaded racks/shelves are all
pulled out at the same time. To prevent tipping, and to
provide stable installation, the unit must be secured in
place with the anti-tip brackets supplied with the unit.
The anti-tip brackets, when properly installed, should
secure the rear legs/glides to the mounting surface
and prevent the unit from tipping forward.
Please note:
► Anti-tip brackets are only used for stationary
cabinets and should not be installed on cabinets
with accessory casters. Caster kits are available
for HC and HB model cabinets. Refer to the
instructions supplied with the caster kit for proper
installation.
► If installing on a concrete floor, concrete fasteners
are required and not included with the anti-tip kit.
► Some installation sites may require modifications
to provide a secure surface for attaching the
brackets.
A set of anti-tip brackets is supplied with the unit.
These brackets should be attached to the floor at
the rear of the unit. Each bracket must be located to
engage the rear glides when the cabinet is pushed
back into position. Refer to Figure 1 (shown below)
for anti-tip bracket mounting locations.
15/16"
3/16"
Figure 1. 24" Anti-Tip Bracket
3
22-1/32"

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hb seriesHd seriesHc seriesHc24 seriesHd24rsHd24ws