When using several ZoneProtects, the
distance from zone wire to zone wire
must be at least 60 cm.
The zone cable must not cross [ Fig. I4 ].
The maximum length of the zone wire
is 15 m.
To connect the zone cable
[ Fig. I1 / I2 ]:
(2)
The zone cable
, the ground hooks
the connection clamps
the scope of delivery.
1. Place the zone cable
zone.
2. Cut both ends of the zone cable
length at the point where you want to set
up the ZoneProtect.
3. Attach one connection clamp
end of the zone cable
4. Attach the connection clamps
(5)
connections
of the ZoneProtect.
5. Secure the ZoneProtect and the zone cable
with the ground hooks
6. Activate the Zone Generator option in
your robotic lawnmower (see Operator's
manual of the robotic lawnmower).
To test the installation:
1. Set the product to ON and make sure that
the LED indicator is green.
2. Make sure that ECO mode of the robotic
lawn mower is disabled.
Refer to ECO Mode in the Operator's
Manual for the robotic lawnmower.
3. Put the robotic lawn mower 1 – 2 m in front
of the stay­out zone. Make sure that the
12
(3)
and
(4)
are not included in
(2)
around the desired
(2)
to
(4)
to each
(2)
.
(4)
to the
(3)
.
robotic lawnmower points forward to the
stay­out zone.
4. Start the robotic lawnmower and make sure
that it stops by the zone boundary wire.
If it enters the stay­out zone, check the con­
ditions for the installation.

3. OPERATION

To charge the battery [ Fig. O1 / O2 ]:
The 5 V power supply unit with USB­A socket
is not included.
The battery is delivered partially charged.
To ensure the full performance of the battery,
fully charge the battery before the first use.
The ZoneProtect cannot be used during
charging.
1. Remove the cover
2. Fold open the sealing cap
3. Plug the USB­C plug of the supplied charg­
ing cable into the charging socket
4. Plug the USB­A plug of the charging cable
into the power supply unit.
5. Connect the power supply unit into a mains
socket.
The battery is charging and the LED
blinks orange.
When the battery is fully charged, the LED
illuminates orange. When the battery is
fully charged, the ZoneProtect works for
approx. 31 days.
LED indicators [ Fig. O2 ]:
By briefly pushing the button
ZoneProtect is displayed for 5 seconds.
(9)
.
(1)
.
(C)
.
(L)
(L)
(8)
the status of