Installation
- Oil feeding and suction line
Burner lower than tank
Burner higher than tank
Burner lower than tank
Burner higher than tank
Pump in suction (H +) or charging (H -)
Altitude (m)
0-500
501-800
801-1300
1301-1800
1801-2200
e.g.: altitude 1100m Theoretical H = 1m actual H 2m, Corrected H for suction 2 + 1 = 3m Corrected H for charging 2 - 1 = 1m.
Choose the Ø of the piping from the table, based on the length expanded between the tank and pump. If corrected H for suction
exceeds 4m; make provisions for a transfer pump (max. pressure 2 bar).
420010474601
Correction of altitude
Theoretical H (m)
0
0,5
1,0
1,5
2,0
FEEDING LINE WITH SUNTEC AS V 47 A
Length pipe (m)
Length pipe (m)
FEEDING LINE WITH DANFOSS BFP21 R3
Length pipe (m)
Length pipe (m)
The length of the tubes apply to
!
burners powered by 50 Hz mains
electricity; in case of 60 Hz
power, divide the relevant
lengths by 1.5.