9
|
Electrical installation
9.3.2 To connect the backup heater power supply
Installer reference guide
112
A
B
C
B
X2M
X1M
A1P
c
b
a Interconnection cable (=main power supply)
b Normal kWh rate power supply
c Preferential power supply contact
3 Fix the cables with cable ties to the cable tie mountings.
INFORMATION
In case of preferential kWh rate power supply, connect X11Y to X11YB. The necessity
of separate normal kWh rate power supply to indoor unit (b) X2M/5+6 depends on
the type of preferential kWh rate power supply.
Separate connection to the indoor unit is required:
▪
if preferential kWh rate power supply is interrupted when active, OR
▪
if no power consumption of the indoor unit is allowed at the preferential kWh
rate power supply when active.
Backup heater type
*6V
*9W
A
6
5
1 2 3
L
N
1N~, 50 Hz,
230 V AC, 6.3 A
C
X11YA
X11YB
X11Y
5 6
1 2 3
X1M
X1A
a
Power supply
1N~ 230 V (6V)
3~ 230 V (6T1)
3N~ 400 V
10 9
S1S
X2M
A1P
Wires
2+GND
3+GND
4+GND
EPRA14~18DAV3+W1 + ETBH/X16EF6V+9W
Daikin Altherma 3 H HT W
4P644736-1 – 2021.02