Installation manual
Daikin Altherma 3 H HT W
https://daikintechnicaldatahub.eu
ETBH16EF6V
ETBH16EF9W
Installation manual
ETBX16EF6V
English
Daikin Altherma 3 H HT W
ETBX16EF9W

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ETBH16EF6V and is the answer not in the manual?

Questions and answers

Summary of Contents for Daikin ETBH16EF6V

  • Page 1 Installation manual Daikin Altherma 3 H HT W https://daikintechnicaldatahub.eu ETBH16EF6V ETBH16EF9W Installation manual ETBX16EF6V English Daikin Altherma 3 H HT W ETBX16EF9W...
  • Page 2 3P644742-1...
  • Page 3: Table Of Contents

    Slope-offset curve ............26 Latest revisions of the supplied documentation may be available on 7.3.4 Using weather-dependent curves ....... 27 the regional Daikin website or via your dealer. Settings menu ................28 ETBH/X16EF6V+9W Installation manual Daikin Altherma 3 H HT W...
  • Page 4: Specific Installer Safety Instructions

    ▪ A subset of the latest technical data is available on the regional Daikin website (publicly accessible). WARNING ▪ The full set of latest technical data is available on the Daikin Due to the presence of glycol, corrosion of the system is Business Portal (authentication required).
  • Page 5: About The Box

    ▪ Space cooling operation: 5~35°C ▪ Domestic hot water production: 5~35°C INFORMATION Cooling is only applicable in case of: ▪ Reversible models ▪ Heating only models + conversion kit (EKHBCONV*) ETBH/X16EF6V+9W Installation manual Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 6: To Close The Indoor Unit

    1 Fix the wall bracket (accessory) to the wall (level) with 2 Ø8 mm 4 If you have to do work behind the user interface panel or upload bolts. new software into the user interface, open the user interface panel. Installation manual ETBH/X16EF6V+9W Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 7: To Connect The Drain Hose To The Drain

    "4.2.1 To open the indoor ▪ Fix the unit to the wall with an Ø8 mm screw. INFORMATION The following illustration is an example and might NOT match your system layout. ETBH/X16EF6V+9W Installation manual Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 8: To Check The Water Volume And Flow Rate

    7H will be generated (no heating or operation). See the installer reference guide for more information. See the recommended procedure as described in "8.2  Checklist during commissioning" [ 4  30]. Installation manual ETBH/X16EF6V+9W Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 9: To Fill The Water Circuit

    — If you add glycol to the water, do NOT install freeze –25°C — protection valves. Possible consequence: Glycol leaking –30°C — out of the freeze protection valves. ETBH/X16EF6V+9W Installation manual Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 10: To Fill The Domestic Hot Water Tank

    See the installation manual of the outdoor unit, or the installer reference guide. Power consumption "6.3.9 To connect the power inputs" [ 4  17]. digital inputs consumption digital Installation manual ETBH/X16EF6V+9W Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 11 ▪ Installation manual of the domestic [9.B.3] Averaging time booster heater (to hot water tank indoor unit) ▪ Addendum book optional equipment Wires: 2+GND Maximum running current: 13 A [9.4] Booster heater ETBH/X16EF6V+9W Installation manual Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 12: To Connect The Main Power Supply

    2 Switch box cover 3 Switch box 2 Connect the main power supply. In case of normal kWh rate power supply Interconnection Wires: (3+GND)×1.5 mm² cable (= main power supply) — Installation manual ETBH/X16EF6V+9W Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 13: To Connect The Backup Heater Power Supply

    3+GND 3N~ 400 V 4+GND Q1DI [9.3] Backup heater Factory-mounted cable connected to the contactor of the backup heater, inside the switch box (K5M) Field wiring (see table below) ETBH/X16EF6V+9W Installation manual Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 14: To Connect The Shut-Off Valve

    Overcurrent fuse (field supply). Recommended fuse: 4‑pole; 20 A; curve 400 V; tripping class C. Safety contactor (in the switch box) Q1DI Earth leakage circuit breaker (field supply) Switch box Terminal (field supply) Installation manual ETBH/X16EF6V+9W Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 15: To Connect The Electricity Meters

    2 Connect the alarm output cable to the appropriate terminals as shown in the illustration below. Wires: (2+GND)×0.75 mm² DHW pump output. Maximum load: 2 A (inrush), 230 V AC, 1 A (continuous) ETBH/X16EF6V+9W Installation manual Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 16: To Connect The Space Cooling/Heating On/Off Output

    3 Switch box 2 Switch box cover 3 Switch box 2 Connect the changeover to external heat source cable to the appropriate terminals as shown in the illustration below. Installation manual ETBH/X16EF6V+9W Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 17: To Connect The Power Consumption Digital Inputs

    2 Connect the safety thermostat (normally closed) cable to the appropriate terminals as shown in the illustration below. Note: The jumper wire (factory-mounted) must be removed from the respective terminals. ETBH/X16EF6V+9W Installation manual Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 18: To Connect A Smart Grid

    Smart Grid relay kit (EKRELSG). The 2 incoming Smart Grid contacts can activate the following Smart Grid modes: Smart Grid contact Smart Grid operation mode Free running Installation manual ETBH/X16EF6V+9W Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 19 3 Connect the high voltage wiring as follows: X10M K1A, K2A Relays X10M Terminal block Screws for X10M Screws for K1A and K2A Sticker to put on the high voltage wires ETBH/X16EF6V+9W Installation manual Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 20: To Connect The Wlan Cartridge (Delivered As Accessory)

    4  29] ▪ "7.5 Menu structure: Overview installer 7.1.1 To access the most used commands To change the user permission level You can change the user permission level as follows: Installation manual ETBH/X16EF6V+9W Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 21: Configuration Wizard

    (User field settings. settings > Time/date) once the unit is initialised. 7.2.3 Configuration wizard: System Indoor unit type The indoor unit type is displayed, but cannot be adjusted. ETBH/X16EF6V+9W Installation manual Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 22 LWT zone. Code Item Third-party tank Coil≥1.05 m² Coil≥1.8 m² 7: 3rd party, 8: 3rd party, [9.2.1] [E‑07] Tank type small coil big coil Installation manual ETBH/X16EF6V+9W Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 23: Configuration Wizard: Backup Heater

    If NOT set the backup heater at nominal voltage is equal to correctly, the liquid in the piping can freeze. [6‑03]+[6‑04]. ETBH/X16EF6V+9W Installation manual Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 24: Configuration Wizard: Main Zone

    T. the storage temperature setpoint is higher than 50°C, Example radiators: 40–10/2=35°C Daikin recommends NOT to disable the backup heater Example underfloor heating: 40–5/2=37.5°C second step because it will have a big impact on the required time for the unit to heat up the domestic hot water To compensate, you can: tank.
  • Page 25: Configuration Wizard: Additional Zone

    Code Description [5.4] [6-0C] Reheat setpoint: ▪ 30°C~min(50,[6‑0E])°C ETBH/X16EF6V+9W Installation manual Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 26: Weather-Dependent Curve

    "7.3.4 Using weather-dependent 7.3.2 2-points curve Define the weather-dependent curve with these two setpoints: ▪ Setpoint (X1, Y2) ▪ Setpoint (X2, Y1) Example Weather-dependent curve when offset is selected: Installation manual ETBH/X16EF6V+9W Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 27: Using Weather-Dependent Curves

    [2.4] Main zone > Setpoint Weather dependent The following table describes how to fine-tune the weather- mode dependent curve of a zone or tank: Additional zone – Heating ETBH/X16EF6V+9W Installation manual Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 28: Settings Menu

    ▪ 2: 2 contacts 7.4.3 Information Dealer information The installer can fill in his contact number here. Code Description [8.3] Number that users can call in case of problems. Installation manual ETBH/X16EF6V+9W Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 29: Menu Structure: Overview Installer Settings

    Solar kit settings are shown but are NOT applicable for this Depending on the selected installer settings and unit type, unit. Settings shall NOT be used or changed. settings will be visible/invisible. ETBH/X16EF6V+9W Installation manual Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 30: Commissioning

    Next commissioning instructions in this chapter, a general ▪ Between the local supply panel and the indoor unit commissioning checklist is also available on the Daikin ▪ Between the indoor unit and the valves (if applicable) Business Portal (authentication required).
  • Page 31: To Check The Minimum Flow Rate

    Purpose Perform an actuator test run to confirm the operation of the different actuators. For example, when you select Pump, a test run of the pump will start. ETBH/X16EF6V+9W Installation manual Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 32: Hand-Over To The User

    ▪ Show the user what to do for the maintenance of the unit. ▪ Explain the user about energy saving tips as described in the operation manual. Installation manual ETBH/X16EF6V+9W Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 33: Technical Data

    10 Technical data Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin Business Portal (authentication required). 10.1 Piping diagram: Indoor unit...
  • Page 34: Wiring Diagram: Indoor Unit

    # Low voltage Smart grid contact  Ext. thermistor  External thermistor SS1 (A4P) * Selector switch  Heat pump convector  Heat pump convector Power supply transformer # Backup heater power supply terminal strip Installation manual ETBH/X16EF6V+9W Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 35 Domestic hot water pump Electrical meters Electrical meters For HV smartgrid For high voltage Smart Grid For LV smartgrid For low voltage Smart Grid For safety thermostat For safety thermostat ETBH/X16EF6V+9W Installation manual Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 36 2 core communication A11P: X9: 1-2-3 2×0.75 Only for Bizone mixing kit X5M: 11-12 A14P: P1-P2 user interface communication 3 core A30P: ST6 A11P: X3: 2-3-4 communication 4D133217A Installation manual ETBH/X16EF6V+9W Daikin Altherma 3 H HT W 4P644727-1 – 2021.02...
  • Page 40 4P644727-1 0000000S 4P644727-1 2021.02 Verantwortung für Energie und Umwelt...