Power Source Powered, Fan (9) Stopped; Power Source Powered, Leds Signaling Doe Not Indicate The Correct Values - Cebora BI-WELDER 1365 Service Manual

Table of Contents

Advertisement

CEBORA S.p.A.

3.3.2 - Power source powered, fan (9) stopped.

FAN TEST.
Fast-on terminals of fan (9) = 230 Vac (with mains 115 or 230 Vac), with switch (5) closed.
♦ Make sure that there are no mechanical impediments blocking the fan.
♦ Replace the fan (9).
♦ Check the wiring between the fan (9) and connection with power board (13).
♦ Replace the power board (13).

3.3.3 - Power source powered, leds signaling doe not indicate the correct values.

LAMP-TEST.
Upon start-up, leds yellow (B) and green (C ) lit for first three seconds, after switch (5)
closed.
♦ Check power source power supply (see par. 3.3.1).
♦ Check voltage supply (see par. 3.4, error codes).
♦ Replace the power board (13).
ERROR CODE TEST.
Upon start-up, after the lamp-test, green led (C) = lit, yellow led (B) = off.
♦ See par. 3.4, error codes.
♦ Replace power board (13).
♦ Correct operation.
3.302.110
Correct?
NO
Correct?
YES
Correct?
YES
YES
NO
NO
8
18/11/02

Advertisement

Table of Contents
loading

This manual is also suitable for:

254

Table of Contents