  • Page 1 MANUAL ENGLISH Performer Profile 600 MKII DDT Ordercode: 33063 Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands...
  • Page 2: Table Of Contents

    Performer Profile 600 MKII DDT Table of contents Warning ....................................3 Safety Instructions ................................. 3 Operating Determinations ............................5 Rigging .................................... 5 Connection with the mains............................6 Return Procedure ................................7 Claims ....................................7 Description of the device ..............................8 Overview ..................................
  • Page 3 Performer Profile 600 MKII DDT Cleaning ....................................25 Cleaning 19°, 26°, 36° and 50° glass lenses ......................25 Cleaning the Reflector ..............................25 Maintenance ..................................26 Replacing the Fuse ..............................26 Troubleshooting ................................26 No Light ..................................26 No Response to DMX..............................27 Product Specifications ..............................28 Dimensions ..................................29 Ordercode: 33063...
  • Page 4: Warning

    Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing. Your shipment includes: ● Showtec Performer Profile 600 MKII DDT ● Safety cable ●...
  • Page 5 ● If your Showtec device fails to work properly, discontinue the use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Showtec dealer for service.
  • Page 6: Operating Determinations

    Performer Profile 600 MKII DDT ● The user is responsible for correct positioning and operating of the Performer. The manufacturer will not accept liability for damages caused by the misuse or incorrect installation of this device. ● This device falls under protection class I. Therefore it is essential to connect the yellow/green conductor to earth.
  • Page 7: Connection With The Mains

    Performer Profile 600 MKII DDT Connection with the mains Connect the device to the mains with the power-plug. Always check if the right color cable is connected to the right place. International EU Cable UK Cable US Cable BROWN YELLOW/COPPER PHASE BLUE BLACK...
  • Page 8: Return Procedure

    Performer Profile 600 MKII DDT Return Procedure Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. Call Highlite 0031-455667723 or mail aftersales@highlite.nl and request an RMA prior to shipping the fixture.
  • Page 9: Description Of The Device

    Performer Profile 600 MKII DDT Description of the device Features The Showtec Performer Profile 600 MKII DDT is a theater spotlight fixture with high output and great effects.  Input voltage: 100-240V AC, 50/60Hz  Power consumption: 250W  Light source: 19 x 10W LED ...
  • Page 10 Performer Profile 600 MKII DDT Fig. 02 01) Lens tube 02) Beam focus control 03) Barrel 04) Mounting bracket 05) LED lens 06) LED board 07) Thermal switch holder + thermal switch 08) Driver board 09) Insulated handle 10) PCB 11) Fuse T6,3AL/250V 12) PS socket 13) PS socket...
  • Page 11: Backside

    Performer Profile 600 MKII DDT Backside Fig. 03 20) Fuse T6,3AL/250V 21) Pro power connector Blue 100-240V IN 22) Pro power connector Gray 100-240V OUT 23) 5-pin DMX signal connector IN 24) 5-pin DMX signal connector OUT 25) 3-pin DMX signal connector IN 26) 3-pin DMX signal connector OUT 27) LCD display + control buttons 28) Input voltage switch 115V/230V...
  • Page 12: Input Voltage Switch

    Performer Profile 600 MKII DDT Input Voltage Switch Flick the voltage switch (28) to choose the desired input voltage: 115V or 230V. Lens Location The different lenses used in the Performer are not interchangeable. When installing a new lens, refer to the illustration below for proper placement.
  • Page 13: Color Frame Retaining Clip

    Performer Profile 600 MKII DDT Color Frame Retaining Clip The color frame holder is equipped with a spring-loaded retaining clip. This prevents color frames and accessories from falling out (fig. 06). Make sure that all color frame accessories are locked in position with the retaining clip before hanging the Performer Profile 600 MKII DDT.
  • Page 14: Shutters

    Performer Profile 600 MKII DDT Shutters The shutters are located inside the barrel. Move them back and forth to modify the shape of the beam. Fig. 07 Drop-in Iris Slot The Drop-in Iris slot is located on the top of the barrel. It accommodates either a drop-in iris or a motorized pattern device.
  • Page 15: Rotating The Barrel Assembly

    Performer Profile 600 MKII DDT Rotating the Barrel Assembly 01) Loosen the barrel rotation control. It can be found directly behind the shutters on the underside of the reflector housing (fig. 09). Do not remove the barrel rotation control. 02) Rotate the barrel to the desired position. 03) Once the barrel is positioned, tighten the barrel’s rotation control to lock it into position.
  • Page 16: Control Modes

    Performer Profile 600 MKII DDT Control Modes There are 3 modes: • Stand-alone • Master/Slave • DMX-512 (1CH, 2CH, 3CH) One Performer (Stand-alone) 01) Fasten the effect light to a firm trussing. Leave at least 0,5 meter on all sides for air circulation. 02) Plug the end of the electric mains power cord into a proper electric power supply socket.
  • Page 17: Multiple Performers (Dmx Control)

    Performer Profile 600 MKII DDT Multiple Performers (DMX Control) 01) Fasten the effect light to a firm trussing. Leave at least 0,5 meter on all sides for air circulation. 02) Always use a safety cable (ordercode 70140 / 70141). 03) Use a 3-pin/5-pin XLR cable to connect the Performers and other devices. 04) Link the units as shown in fig.
  • Page 18: Fixture Linking

    Performer Profile 600 MKII DDT Fixture Linking You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run synchronized shows of two or more fixtures set to a master/slave operating mode. The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support.
  • Page 19: Control Panel

    Performer Profile 600 MKII DDT The Performer Profile 600 MKII DDT can be operated with a controller in control mode or without the controller in stand-alone mode. Control Panel A) MENU button ENTER button C) DOWN button D) UP button LCD display Fig.
  • Page 20: Menu Overview

    Performer Profile 600 MKII DDT Menu Overview Ordercode: 33063...
  • Page 21: Main Menu Options

    Performer Profile 600 MKII DDT Main Menu Options 01) On start-up, the display will show information about the device’s current status: 02) Press the ENTER button to open the main menu. 03) Press the UP/DOWN buttons to toggle through the 4 main menu options: 04) Press the ENTER button to open the desired submenu.
  • Page 22: Run Mode

    Performer Profile 600 MKII DDT 2. Run Mode In this mode you can set the desired operation mode. 01) While in main menu, press the UP/DOWN buttons until the display shows RUNMODE. 02) Press the ENTER button to open the menu. 03) Press the UP/DOWN buttons to toggle through the 4 options: ...
  • Page 23: Safety Key

    Performer Profile 600 MKII DDT 4.1. Safety Key 01) When the display shows KEY, press the ENTER button to open the menu. 02) Press the UP/DOWN buttons to toggle between ON and OFF to activate/deactivate the safety lock. 03) When the option is active, you will need to insert the safety key combination every time the display turns off.
  • Page 24: Dmx Channel Modes

    Performer Profile 600 MKII DDT 4.6. DMX Channel Modes With this menu you can set the desired DMX channel mode. 01) When the display shows PERSONALITY, press the ENTER button to open the menu. 02) Press the UP/DOWN buttons to toggle through the 3 channel modes: 1-channel mode 2-channel mode STD.P...
  • Page 25: Dmx Channels

    Performer Profile 600 MKII DDT DMX Channels 1 Channel (UNO) Channel 1 – Dimmer 0-255 0-100% dimmer 2 Channels (DOS) Channel 1 – Dimmer 0-255 0-100% dimmer Channel 2 – Fine dimmer CH1 must be open. 0-255 Fine dimmer adjustment 3 Channels (STD.P) Channel 1 –...
  • Page 26: Cleaning

    Performer Profile 600 MKII DDT Cleaning Please follow the next recommendations when cleaning and inspecting lenses and reflectors: Do not use glass or window type cleaners on lenses (glass or polymer) or reflectors. Do not use abrasive materials such as steel wool. Replace lenses if they contain visible damage (cracks or deep scratches) which that may impair their effectiveness.
  • Page 27: Maintenance

    Suspect three potential problem areas as: the power supply, the LEDs, the fuse. 01) Power supply. Check if the unit is plugged into an appropriate power supply. 02) The LEDs. Return the Performer to your Showtec dealer. 03) The fuse. Replace the fuse. See page 26 for replacing the fuse.
  • Page 28: No Response To Dmx

    Performer Profile 600 MKII DDT No Response to DMX Suspect the DMX cable or connectors, a controller malfunction, a light effect DMX card malfunction. 01) Check the DMX setting. Make sure that DMX addresses are correct. 02) Check the DMX cable: Unplug the unit; change the DMX cable; then reconnect to electrical power. Try your DMX control again.
  • Page 29: Product Specifications

    Performer Profile 600 MKII DDT Product Specifications Model: Showtec Performer Profile 600 MKII DDT Input voltage: 100-240V AC, 50/60Hz Power consumption: 250W (full output) DMX linking: 30pcs Fuse: T6,3AL/250V Dimensions: 480 x 290 x 462 mm (LxWxH) Weight: 8,2 kg...
  • Page 30: Dimensions

    Performer Profile 600 MKII DDT Dimensions Ordercode: 33063...
  • Page 31 Performer Profile 600 MKII DDT Ordercode: 33063...
  • Page 32 ©2017 Showtec...

This manual is also suitable for:

33063

Table of Contents