Omron ZS-HL-N Series Command Reference Manual page 15

Smart sensors

Advertisement

Setting Threshold Value
When multi-task mode is OFF
• When selecting a mode other than "GLASS/MODE 2" and "GLASS THICKNESS/
MODE 2".
Unit No.
Data No.
48
2
3
4
5
6
• When selecting "GLASS/MODE 2" or "GLASS THICKNESS/MODE 2" mode.
Unit No.
Data No.
88
2
3
4
5
6
When multi-task mode is ON
• Can be set for each TASK.
Unit No.
Data No.
48
2
3
4
5
6
Parameter
Setting range/Output range
Lower limit of
-999999999 to 999999999 (nm)
threshold
Upper limit of
-999999999 to 999999999 (nm)
threshold
Hysteresis width
0 to 999999999 (nm)
Timer mode
0:OFF
1:OFF DELAY
2:ON DELAY
3:ONE SHOT
Delay time
1 to 5000 (ms)
Parameter
Setting range/Output range
Lower limit of
-999999999 to 999999999 (nm)
threshold
Upper limit of
-999999999 to 999999999 (nm)
threshold
Hysteresis width
0 to 999999999 (nm)
Timer mode
0:OFF
1:OFF DELAY
2:ON DELAY
3:ONE SHOT
Delay time
1 to 5000 (ms)
Parameter
Setting range/Output range
Lower limit of
-999999999 to 999999999 (nm) TASK1 settings.
threshold
Upper limit of
-999999999 to 999999999 (nm)
threshold
Hysteresis width
0 to 999999999 (nm)
Timer mode
0:OFF
1:OFF DELAY
2:ON DELAY
3:ONE SHOT
Delay time
1 to 5000 (ms)
Non-procedural Communication Command Reference
List of Parameters
Others
Others
Others
For TASK2 to
TASK4, the unit
numbers are as
follows:
TASK2: 68
TASK3: 88
TASK4: 108
ZS-HL-N Series
13