    CONTENTS | SPECiAl iNfOrmATiON SPECiAl iNfOrmATiON SPECIAL INFORMATION OPERATION General information �����������������������������������������3 Safety instructions ����������������������������������������������� 3 - This appliance is not intended for use by per- Other symbols in this documentation ����������������������� 3 sons (including children) with reduced phys- Information on the appliance ��������������������������������� 3 ical, sensory or mental capabilities, or lack Units of measurement ������������������������������������������...
  • Page 3: General Information

    OPErATiON General information OPErATiON Other symbols in this documentation Note General information is identified by the adjacent symbol. f Read these texts carefully. General information The chapters "Special information" and "Operation" are intended Symbol meaning for both users and qualified contractors. Material losses The chapter "Installation"...
  • Page 4: General Safety Instructions

    OPErATiON Appliance description General safety instructions Test symbols See type plate on the appliance. WARNING Injury - This appliance is not intended for use by persons Appliance description (including children) with reduced physical, sensory or mental capabilities, or lack of experience and The appliance is a wall mounted electric direct heater for areas knowledge, unless they have been given supervi- such as workspaces, kitchens, bathrooms and similar.
  • Page 5: Switching The Appliance On And Off

    OPErATiON CK 20 Premium (AU) operation Switching the appliance on and off Programming unit The appliance is operated using the programming unit which is Note located at the top right of the appliance front. For a short time after initial start-up and after longer breaks in use, a smell may develop briefly.
  • Page 6: Switching The Appliance On And Off

    OPErATiON CK 20 Premium (AU) settings 5.1.2 Display All settings remain intact after switching off or after an interrup- tion to the power supply. This appliance is equipped with a power If no user action occurs for 20 seconds, the backlighting switches reserve that ensures the day of the week and the time are saved off.
  • Page 7: Standard Menu

    OPErATiON CK 20 Premium (AU) settings Standard menu The standard display shows the selected time in minutes as well as the "Editable parameter" symbol. Using the "+" and "-" buttons, To access the standard menu, briefly press "Menu". You can now you can select any length of time from 10 - 120 minutes.
  • Page 8 OPErATiON CK 20 Premium (AU) settings 6.4.1 Actual values Note The following actual values can be called up: When time program Pro2 is enabled, the appliance oper- ates at weekends exclusively in setback mode. Display Description Unit Actual room temperature [°C] | [°F] To adapt time programs Pro1 and Pro2 according to your needs, Relative heating time proceed as follows:...
  • Page 9: Cleaning, Care And Maintenance

    OPErATiON Cleaning, care and maintenance Troubleshooting 6.4.3 Parameter You can call up the following parameters: Problem Cause remedy Room does not get Temperature set too low Check the temperature set Display Description Options warm enough. Ap- on the appliance. on the appliance. Adjust if Room temperature offset ±3 °C | ±5 °F pliance does not get...
  • Page 10: Installation

    iNSTAllATiON Safety iNSTAllATiON 11. Installation 11.1 Minimum clearances Safety Only a qualified contractor should carry out installation, commis- sioning, maintenance and repair of the appliance. General safety instructions ≥100 ≥100 ≥500 We guarantee trouble-free function and operational reliability only if original accessories and spare parts intended for the appliance are used.
  • Page 11: Appliance Installation

    iNSTAllATiON Commissioning 11.5 Electrical connection f Lift up the wall mounting bracket so that its lower holes match up with the markings you have just made on the in- stallation wall. WARNING Electrocution f Mark holes 3 and 4 on the installation wall. - Carry out all electrical connection and installation work in accordance with relevant regulations.
  • Page 12: Specification

    iNSTAllATiON | ENVirONmENT AND rECYCliNG Specification 15. Specification 15.2 Data table CK 20 Plus (AU) CK 20 Premium 15.1 Dimensions and connections (AU) 202084 202085 CK 20 Plus (AU) Electrical data Connected load 2000 2000 Power supply 1/N/PE ~ 230 V 1/N/PE ~ 230 V Voltage range 230-240...
  • Page 13: Warranty

    Who gives the warranty The contact details for you to make your warranty claim are: The warranty is given by Stiebel Eltron (Aust) Pty Ltd (A.B.N. Name: Stiebel Eltron (Aust) Pty Ltd 82 066 271 083), 294 Salmon Street, Port Melbourne, Victoria,...
  • Page 14 The Stiebel Eltron warranty for the unit is in addition to any rights and remedies you may have under the Australian Consumer Law.
  • Page 15 NOTES www.stiebel-eltron.com CK 20 Plus (AU) | CK 20 Premium (AU) |...
  • Page 16 Hungary South Africa STIEBEL ELTRON Australia Pty. Ltd. STIEBEL ELTRON Kft. STIEBEL ELTRON Southern Africa (PT Y) Ltd 294 Salmon Street | Port Melbourne VIC 3207 Gyár u. 2 | 2040 Budaörs 30 Archimedes Road Tel. 03 9645-1833 | Fax 03 9644-5091 Tel.

This manual is also suitable for:

Ck 20 premium au202084202085

Table of Contents