Inspect the trigger, spring, and the safety mechanism for free movement on a regular
basis in order to ensure that the safety system is fully functional. Verify that no part is
loose or missing and that no parts are sticking or jammed.
Keep the magazine and the safety tip of the tool clean and free of any dirt or abrasive
particles
Air-operated tools must be inspected periodically, and worn or broken parts must be
replaced in order to keep tools operating safely and efficiency.
Inspect and replace worn or damaged 0-rings, seals, etc. Tighten all screws and caps
frequently in order to help prevent personal injury.
If any of the following symptoms appear while the tool is in use,
turn it off and disconnect it from the air supply immediately.
Failure to comply will lead to serious injury or loss of life.
Disconnect the tool from the air supply before making any adjustments.
Repairs must be performed by a qualified service technician only.
The following chart lists common issues and solutions. Please read it
carefully and follow all instructions carefully.
Air leakage at
the top of the
tool or in the
trigger area.
Air leakage
near the
bottom of the
tool.
Air leakage
between
the bottom
and the
cylinder
cap.
1. O-rings in the trigger
valve are damaged.
2. The trigger valve
heads are damaged.
3. Trigger valve stem,
seal, or O-rings are
damaged.
1. The screws are loose.
2. The O-rings or the
bumper is worn or
damaged.
1. The screws are loose.
2. The O-rings or the
seals are worn or
damaged.
1. Inspect and replace the O-ring.
2. Inspect and replace trigger valve
heads.
3. Inspect and replace the trigger
valve stem, seal, or O-ring
1. Tighten the screws.
2. Inspect and replace the O-rings
or the bumper.
1. Tighten the screws.
2. Inspect and replace the O-rings
or the seals.