18 gauge pneuma tic brad nailer

Advertisement

Always use clean, dry, regulated, compressed air at 4.1 to 6.9bar (60-100PSI)
Do not exceed the maximum or minimum pressures. Operating the tool at the wrong
pressure (too low or too high) will cause excessive noise or rapid wear of tool.
18-gauge pneumatic brad
1
nailer
2
Quick connector
3
Quick coupler
4
Air hose
Lubricator
5
The use of any other types of fasteners will cause the tool to jam. Failure
to comply could lead to serious injury or loss of life.
It is recommended that a lter-regulator-lubricator is used and located as close to the tool as
possible.
If a lter-regulator-lubricator is not installed, place up to 6 drops of compressor oil into the
NPT inlet plug before each use.
If a lter-regulator-lubricator is installed, keep the air lter clean. A dirty lter will reduce the
air pressure to the tool, which will cause reduction in power, efficienc , and general
performance.
For optimal performance, install a quick coupler in the hose, if applicable.
Verify that all of the connections in the air supply system are sealed in order to prevent air
from leaking.
6
0 to 6.9 bar
Filter
7
Cut-off al e
8

Air compressor

9

Advertisement