Item
Start level
Stop level
Relay
Function
Polarity
Services
ModbusTCP
MQTT on LAN (SSL)
MQTT on LAN (Plaintext)
VE.Can port
CAN-bus
I/O
Page 43
Color Control GX Manual
Default
Description
50%
The trigger point of the tank level to start the tank pump (close the
relay).
80%
The trigger point of the tank level to stop the tank pump (open the
relay).
Alarm relay
Select the relay function. Possible functions are 'Alarm relay',
'Generator start/stop', 'Tank pump', 'Temperature', and 'Manual'.
Normally open
Select the polarity of the relay on the back of the CCGX.
'Normally open' or 'Normally closed'. Note that setting it to
Normally closed increases the CCGX power draw. This option is
only available when configured as an alarm relay.
Off
This setting enables the ModbusTCP service. More information
about
white paper
documents/Whitepaper-Data-communication-with-Victron-Energy-
products_EN.pdf
On
Enables MQTT on LAN - More information on MQTT is available
on
Victron Community.
Off
This setting is required to be enabled when connecting a Marine
MFD
VE.Can
CAN-bus profile (Disabled, VE.Can & Lynx Ion BMS 250 kbit/s,
VE.Can & Can-bus BMS 250 kbit/s, CAN-bus BMS 500 kbit/s,
Oceanvolt 250 kbit/s, RV-C 250 kbit/s). Additional options:
Devices, NMEA2000-out, Unique identity number selector, Check
unique ID numbers, Network status
CAN-bus profile, Send data to VE.Can, Unique device number for
VE.Can, Check unique numbers
ModbusTCP in this document
and in the communications
https://www.victronenergy.com/upload/
Configuration