Victron energy Color Control GX Manual page 47

Hide thumbs Also See for Color Control GX:
Table of Contents

Advertisement

Item
IP address
Netmask
Gateway
DNS server
Link-local IP address
WiFi -
Read full feature description [30]
Create access point
Wi-Fi networks
Name
State
Forget network
Signal strength
MAC address
IP configuration
IP address
Netmask
Gateway
DNS server
GSM modem -
Read full feature description
GPS -
Read full feature description [13]
GPS information
Device
Format
Speed unit
Generator start/stop -
Read full feature description [100]
State
Error
Total run time
Time to next test run
Auto start functionality
Manual start
Daily run time
Generator start/stop → Settings
Generator start/stop → Settings → Conditions
On loss of communication
Do not run generator when
AC1 is in use
Page 41
Color Control GX Manual
Default
Description
-
-
-
-
-
Enabled
Disables the internal WiFi access point
-
Displays a list of available WiFi networks and/or the network to
which the GX device is connected
-
SSID of the Wifi network
Connected
-
Press to "forget" the network if you want to connect to a different
network or troubleshoot
%
-
Automatic
Options: Automatic (DHCP) and manual IP address allocation
-
-
-
-
-
Status, Latitude, Longitude, Speed, Course, Altitude, Number of
satellites
-
Displays device related information for diagnostic
DDD.DDDDD°
Choose between decimal degrees, degrees and decimal minutes
or degrees, minutes and seconds display
km/h
Choose between km/h, meters per second, miles per hour, or
knots.
Stopped
Displays if the generator is running or not
No error
Displays if there is an error (e.g. generator is supposed to be
running but no AC input is detected)
hh:mm
Total time the generator has been running since reset.
hh:mm
If a periodic run is programmed, this counter will display in days,
and hours how long before that will occur.
Disabled
Enable or disable the Autostart functions, this can be further
configured in the Generator → Settings → Conditions menu
-
Start generator, Run for hh:mm
-
Submenu shows the history of time the generator has been
running (minutes) each day for the previous 30 days.
Stop generator
Stop, Start, Keep generator running
No
This option is ideal for back-up systems where a Quattro has
mains/grid electricity connected to its AC-in 1 terminal, and
a Genset connected to its AC-in 2 terminal. With this option
enabled, the Genset will only start after a mains failure.
Configuration

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cerbo-s gxVenus gx

Table of Contents