Siemens RUGGEDCOM RMC8388 Installation Manual page 45

Simatic net rugged ethernet switches
Table of Contents

Advertisement

Certification
6.2 EMC and Environmental Type Tests
IEEE 1613 EMC Immunity Type Tests
Note
RUGGEDCOM products meet Class 1 requirements for copper Ethernet
configurations and Class 2 for fiber Ethernet configurations. Class 1 allows for
temporary communication loss, while Class 2 requires error-free and interrupted
communications.
Fast Transient
Dielectric Strength
Environmental Type Tests
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-14
IEC 60068-2-30
IEC 60068-2-31
36
Description
ESD
Radiated RFI
Oscillatory
HV Impulse
Test
Description
Cold Operation
Cold Storage
Dry Heat
Operation
Dry Heat
Storage
Change of Temperature
Humidity
(Damp
Heat, Cyclic)
Enclosure Contact
Enclosure Air
Enclosure Ports
Signal Ports
DC Power Ports
AC Power Ports
Earth Ground Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Test Ad
Test Ab
Test Bd
Test Bb
5 cycles at -40 to 85 °C (-40 to
185 °F) and 3 hour dwells at
rate of 1 °C/min (1.8 °F/min)
Test Db
humidity (non-condensing)
Free Fall
Test Levels
± 2 kV, ± 4 kV, ± 8 kV
± 4 kV, ± 8 kV, ± 15 kV
35 V/m
± 4 kV @ 2.5 kHz
± 4 kV
± 4 kV
± 4 kV
2.5 kV Common mode @ 1MHz
2.5 kV Common, 1 kV
Differential Mode @ 1MHz
2.5 kV Common, 1 kV
Differential Mode @ 1MHz
5 kV (Failsafe Relay)
5 kV
5 kV
2 kVAC
2.8 kVDC
2 kVAC
Test Levels
16 hours at -40 °C (-40 °F)
16 hours at -40 °C (-40 °F)
16 hours at 85 °C (185 °F)
16 hours at 85 °C (185 °F)
6 cycles at 55 °C (131
°F) and 95% relative
Procedure 1, 2 falls from a
height of 250 mm (9.8 in)
Installation Manual, 11/2022, C79000-G8976-1188-05
Severity
Levels
 
 
 
 
 
 
 
RUGGEDCOM RMC8388

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic net ruggedcom rmc8388

Table of Contents