Zennio MAXinBOX 66 Technical Documentation

Multi-function actuator 6 outputs 16a and 6 a/d inputs
Hide thumbs Also See for MAXinBOX 66:

Advertisement

Quick Links

MAXinBOX 66. Multi-function actuator 6 outputs 16A and 6 A/D inputs
ZN1IO-MB66
FEATURES
 3 different configurable channels:
shutter channels (up to 3)
individual outputs (up to 6)
 6 analog/digital inputs.
 Manual output operation with push button and LED
status indicator.
 Logical functions included.
 Output timing facilities.
 Total data saving on power failure.
 Size 67 x 90 x 79 mm (4.5 DIN units).
DIN rail mounting (EN 50022), through pressure.
 KNX BCU integrated.
 Suitable for capacitive loads, maximum 140 µF.
 Possibility to connect different phases in adjoining outputs.
 Conformity with the CE directives (CE-mark on the right side).
1. Analog/Digital inputs
5. Programming/Test LED
Programming/test button: short press to set programming mode. If this button is held while plugging the device into the KNX bus, it enters the safe
mode. If this button is held for more than 3 seconds, the device enters the test mode.
Programming/Test LED: programming mode indicator (red). When the device enters into safe mode, it blinks (red) every half second. The manual
mode is indicated by the green color. During the start-up (reset or after KNX bus failure) and if the device is not in safe mode, it starts a blue blinking
sequence.
GENERAL SYSTEM SPECIFICATIONS
CONCEPT
Type of device
Voltage (typical)
Voltage range
KNX
Maximum
supply
consumption
Bus connection
External power supply
Operation temperature
Storage temperature
Operation humidity
Storage humidity
Complementary characteristics
Protection class
Operation type
Device action type
Electrical stress period
Degree of protection
Minimum clearances
Installation
Response on KNX bus failure
Response on KNX bus restart
Operation indication
Weight
PCB CTI index
Housing material
(1)
Maximum consumption in the worst case scenario (KNX Fan-In model)
© Zennio Avance y Tecnología S.L.
2. Upper outputs
6. Lower outputs
DESCRIPTION
Electric operation control device
29VDC SELV
21...31VDC
Voltage
29VDC (typical)
(1)
24VDC
Typical TP1 bus connector for rigid cable 0.80mm Ø
No
from 0ºC to +55ºC
from -20ºC to +70ºC
5 to 95% RH (no condensation)
5 to 95% RH (no condensation)
Class B
II
Continuous operation
Type 1
Long
IP20, clean environment
Not required
Independent device to be mounted inside electrical panels with DIN rail (EN 50022).
Data saving and relay status change according to parameterization.
Data recovering and output status change according to parameterization.
Programming LED indicates programming mode (red) and test mode (green). Output
status LED indicators reflect current output state.
264g
175V
PC FR V0 halogen free
Edition 8
3
4
5
Figure 1. MAXinBOX 66
3. Output status LED indicator
7. KNX connection
mA
7
10
Further information
www.zennio.com
MAXinBOX 66
Technical Documentation
1
2
8
7
6
4. Output control button
8. Programming/Test button
mW
203
240
Page. 1 / 2

Advertisement

loading

Summary of Contents for Zennio MAXinBOX 66

  • Page 1 MAXinBOX 66 MAXinBOX 66. Multi-function actuator 6 outputs 16A and 6 A/D inputs Technical Documentation ZN1IO-MB66 FEATURES  3 different configurable channels:  shutter channels (up to 3)  individual outputs (up to 6)  6 analog/digital inputs.  Manual output operation with push button and LED status indicator.
  • Page 2 In order to ensure the expected status of the relays, please check that the device is connected to the KNX bus before energizing the power circuit. Attaching MAXinBOX 66 to DIN rail: INPUT SPECIFICATIONS AND CONNECTIONS CONCEPT...