4

Requirements

4.1

Requirements on the location

Never use combustible building materials for the fireplace.
Do not install the appliance against a flammable rear wall.
Install a nonflammable insulation plate of at least 12 mm between the appliance and
the rear wall. The insulation plate must cover the entire area of the rear of the
appliance.
The appliance must be installed approximately 2 cm from the rear wall.
If the fire burns in the appliance, make sure that the floor temperatures below and in
front of the appliance cannot be higher than 85 °C .
Make sure that the room where the appliance is installed is properly ventilated.
4.2

Other requirements

The gas supply connection is located under in the appliance for an easy connection to
all directions.
Only use gas piping of at least 1/2" and a shut-off valve to connect the gas supply to
the gas regulator block of the appliance.
Make sure that there is a wall socket with earth connection nearby the appliance. The
socket must be accessible at all times. The powercable (+ 0.5 m) is coming from the
rear of the appliance.
Install the fireplace on a solid floor that can bear the weight of the appliance and the
fireplace.
If the floor is made of flammable material, take correct safety measures. Install a
temperature protection plate made of nonflammable material between the appliance
and the floor.
The appliance must be installed into an existing open fireplace or as a built-in
appliance in a new fireplace.
If the concentric flue system is installed in a chimney that is used for wood or coal fire,
clean the chimney.
If you built a new fireplace, make sure that it is ventilated with vents at the bottom and
top of the fireplace. If the fireplace is not ventilated the temperature of the appliance
can increase to dangerous temperatures and damage the fireplace.
Keep a minimum distance between the appliance and a front wooden fireplace
surround; with a depth of less than 10 cm, of:
4.3

Requirements on the outlet

4.3.1

Requirements on the roof outlet

Make sure that the outlet is installed at least 0.5 meter from the edge of the roof.
Smart Bell 80-60
5 cm on the sides: (minimum distance: side appliance - leg wooden fireplace
surround)
40 cm at the top: (minimum distance: top appliance - bottom of beam wooden
fireplace surround) The temperature on the underside of the beam of the wooden
fireplace must never exceed 85°C. Optional: insulate the bottom of the wooden
beam with a fireproof plate.
Note:
All the minimum distances are guidelines. Consult your national and local
directives for the exact minimum distances.