Opening Door; Room Air Fan; Shutdown Procedure - United States Stove US5513 Owner’s Instruction And Operation Manual

Table of Contents

Advertisement

Available languages

Available languages

OPENING DOOR

CAUTION:
• DO NOT OPERATE YOUR STOVE WITH THE
VIEWING DOOR OPEN. THE AUGER WILL NOT
FEED PELLETS UNDER THESE CIRCUMSTANCES
AND A SAFETY CONCERN MAY ARISE FROM
SPARKS OR FUMES ENTERING THE ROOM.
• THE FEED DOOR MUST BE CLOSED AND SEALED
DURING OPERATION.
If the door is opened while the stove is in operation it
must be closed within 30 seconds or the stove will shut
down. If the stove shuts down push the "On/Off" button
to re-start your stove. The stove will have to fully shut
down and turn off before you will be able to restart the
stove.

ROOM AIR FAN

When starting your stove the Room Air Fan will not
come on until the stove's heat exchanger warms up. This
usually takes about 10 minutes from start-up.
IF STOVE RUNS OUT OF PELLETS
The fire goes out and the auger motor and blowers will
run until the stove cools. This will take 30 minutes or
longer depending on the heat remaining in the appliance.
After the stove components stop running all lights on
the display will go out and the two digit display will begin
flashing "E3"
REFUELLING
CAUTION:
• THE HOPPER AND STOVE TOP WILL BE HOT
DURING
OPERATION;
SHOULD ALWAYS USE SOME TYPE OF HAND
PROTECTION WHEN REFUELING YOUR STOVE.
• DO NOT TOUCH THE HOT SURFACES OF THE
STOVE. EDUCATE ALL CHILDREN ON THE
DANGERS OF A HIGH-TEMPERATURE STOVE.
YOUNG CHILDREN SHOULD BE SUPERVISED
WHEN THEY ARE IN THE SAME ROOM AS THE
STOVE.
• NEVER PLACE YOUR HAND NEAR THE AUGER
WHILE THE STOVE IS IN OPERATION.
• WE RECOMMEND YOU NOT LET THE HOPPER
DROP BELOW 1/4 FULL.
© 2022 United States Stove Company
OPERATION INSTRUCTIONS
THEREFORE,
YOU
WARNING:
• KEEP HOPPER LID CLOSED AT ALL TIMES
EXCEPT WHEN REFILLING.
• DO NOT OVERFILL HOPPER.
TAMPER WARNING
This wood heater has a manufacturer-set minimum low
burn rate that must not be altered. It is against federal
regulations to alter this setting or otherwise operate this
wood heater in a manner inconsistent with operating
instructions in this manual.

SHUTDOWN PROCEDURE

WARNING:
NEVER SHUT DOWN THIS UNIT BY UNPLUGGING
IT FROM THE POWER SOURCE.
Turning your stove off is a matter of pressing the "POWER"
button on the display board. The green light will turn back
to red when the "POWER" button is pushed. The auger
motor will stop, and the blowers will continue to operate
until the internal firebox temperatures have fallen to a
preset level.
1.
Your stove is equipped with a high temperature
thermodisc. This unit has a manual reset thermodisc.
This safety switch has two functions.
A. To recognize an overheat situation in the stove and
shut down the fuel feed or auger system.
B. In case of a malfunctioning convection blower, the
high-temperature thermodisc will automatically
shut down the auger, preventing the stove from
overheating.
NOTE: On some units, once tripped, like a circuit breaker,
the reset button will have to be pushed before restarting
your stove. On other units the thermodisc has no reset
button and will reset itself once the stove has cooled.
The manufacturer recommends that you call customer
service if this occurs as this may indicate a more serious
problem. A service call may be required.
2. If the combustion blower fails, an air pressure switch
will automatically shut down the auger.
NOTE: Opening the stove door for more than 30 seconds
during operation will cause enough pressure change to
activate the air switch, shutting the fuel feed off. The stove
will shut down and show "E2" on the two digit display.
The stove has to fully shut down before restarting.
14

Advertisement

Table of Contents
loading

Table of Contents