United States Stove KING KP5522 Owner’s Instruction And Operation Manual
United States Stove KING KP5522 Owner’s Instruction And Operation Manual

United States Stove KING KP5522 Owner’s Instruction And Operation Manual

Hide thumbs Also See for KING KP5522:

Advertisement

Quick Links

Owner's Instruction and Operation Manual
Model Number:
KP5522
Report Number: F22-782
Certified to ASTM E1509-12 (2017)
and ULC-S627-00-REV1
Mobile Home Approved
* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
Save These Instructions In A Safe Place For Future Reference.
SAFETY NOTICE: If this heater is not properly installed, a house fire may result. For
your safety, follow the installation instructions. Never use make-shift compromises
during the installation of this heater. Contact local building or fire officials about
permits, restrictions and installation requirements in your area. NEVER OPERATE
THIS PRODUCT WHILE UNATTENDED.
CAUTION! Please read this entire manual before you install or use your new room
heater. Failure to follow instructions may result in property damage, bodily injury, or
even death. Improper Installation Will Void Your Warranty!
U.S. Environmental Protection Agency
Certified to comply with 2020 particulate
emissions standards.
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
© 2022 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380
R
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon
monoxide, which is known to the State of California to cause
cancer, birth defects, and/or other reproductive harm. For
more information, go to
853930-2304L
www.P65warnings.ca.gov
Ph. 800-750-2723

Advertisement

Table of Contents
loading

Summary of Contents for United States Stove KING KP5522

  • Page 1 State of California to cause cancer, birth defects, and/or other reproductive harm. For emissions standards. more information, go to www.P65warnings.ca.gov THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE. © 2022 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380 Ph. 800-750-2723...
  • Page 2 This app is available only Text to 423-301-5624 or; on the App Store for iPhone and iPad. Email us at: Search US Stove. Save your receipt with customerservice@usstove.com your records for any claims. © 2022 United States Stove Company...
  • Page 3: Installation Checklist

    Declaration of Completion: As the qualified person responsible for the work described above, I confirm that the appliance as associated work has been installed as per manufacturer’s instructions and following any applicable building and installation codes. Signed: ______________________________________ Print Name: __________________________________Date: ______________ Home Owner: RETAIN THIS INFORMATION FOR FUTURE REFERENCE © 2022 United States Stove Company...
  • Page 4: Installation

    2. Unpack the top mount controls and ensure that the wiring harness shown is attached securely. 4. Secure the control panel to the top of the stove with two sheet metal screws. © 2022 United States Stove Company...
  • Page 5: Installation Options

    AND CAN BE HAZARDOUS TO YOUR HEALTH IF with clearance requirements for a freestanding stove NOT PROPERLY VENTED. installation. Alcove Unit - supported by pedestal/legs and placed © 2022 United States Stove Company...
  • Page 6: Floor Protection

    For safety reasons, please adhere to the installation clearances and restrictions. Any reduction in clearance to combustibles may only be done by means approved by a regulatory authority. © 2022 United States Stove Company...
  • Page 7: Outside Air Supply

    The maximum recommend vertical venting height is 12- the floor of the home. feet for 3-inch type “PL” vent. Total length of horizontal © 2022 United States Stove Company...
  • Page 8: Pellet Vent Termination

    Vent surfaces can get hot enough E. Minimum 2-foot (0.61m) clearance above any grass, to cause burns if touched by children. Noncombustible plants, or other combustible materials. shielding or guards may be required. © 2022 United States Stove Company...
  • Page 9 4 inch “PL” pellet venting products. The use of other of vertical venting. An approved vertical vent cap is components other than stated herein could cause bodily recommended. harm, heater damage, and void your warranty. © 2022 United States Stove Company...
  • Page 10: Through The Wall Installation

    If clearance through a combustible wall. Once outside the an offset is required, it is better to install 45-degree structure, a 3” (76 mm) clearance should be maintained elbows rather than 90-degree elbows. © 2022 United States Stove Company...
  • Page 11 860001, 3-6” transition into 6” connector pipe. the illustration is only an example. Please conform to any local building codes or regulations having jurisdiction before you have a qualified installer proceed with this installation. © 2022 United States Stove Company...
  • Page 12 • The levels of heat output will incrementally change on the bar graph starting from heat range “1” to heat range • When room temperature drops below desired set-point “5”. the stove will ramp back up until it reaches the desired temperature. © 2022 United States Stove Company...
  • Page 13: Control Panel Overview

    When adjusting the Draft Fan setting, try only 1 setting above or below the heat setting. It is better to leave the stove in the automatic mode. © 2022 United States Stove Company...
  • Page 14: Thermostat Hook-Up

    T’Stat requires more heat, the unit will begin to feed pellets at the preselected heat setting ranging from “1” to “5”. Use 18 gauge, 2 conductor wire © 2022 United States Stove Company...
  • Page 15: Proper Fuel

    Your pellet stove is designed to burn premium hardwood WHILE THE STOVE IS PLUGGED IN. pellets that comply with the Pellet Fuels Institute (PFI) standard (minimum of 40 lbs density per cubic ft, 1/4” to © 2022 United States Stove Company...
  • Page 16: Optimal Operation

    • WE RECOMMEND THAT YOU NOT LET THE the “Heat Level Advance” button. HOPPER DROP BELOW 1/4 FULL. If the fire doesn’t start in 12 minutes, press “On/Off”, wait a few minutes, clear the burn pot, and start the procedure again. © 2022 United States Stove Company...
  • Page 17: Shutdown Procedure

    The stove will shut down and show “E2” on the two digit display. The stove has to fully shut down before restarting. © 2022 United States Stove Company...
  • Page 18: Maintenance

    CO. the top as well as from the bottom. The creosote should be removed with a brush specifically designed for the © 2022 United States Stove Company...
  • Page 19: Spring Shutdown

    Gaskets Inspected 5. Re-install the retainer and eight nuts and rope gasket Glass Wiped Cleaned using high-temperature silicone to adhere the gasket Hopper (end of Empty & to the door. season) Vacuumed © 2022 United States Stove Company...
  • Page 20: Troubleshooting Guide

    ATTENTION: THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH OPERATING INSTRUCTIONS IN THIS MANUAL. © 2022 United States Stove Company...
  • Page 21: Display Indicators

    FACTORY DEFAULTS To return the control to its original factory default settings, press and hold the AUX UP and AUX DOWN buttons together for three seconds. © 2022 United States Stove Company...
  • Page 22: Repair Parts

    Door Handle Kit 88118 Ignitor Flange Gasket IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING USSC PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM USSC. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY. © 2022 United States Stove Company...
  • Page 23: Wiring Diagram

    Part numbers and descriptions can be found in the “Repair Parts” section of this manual. Once this information has been gathered you can contact customer service by phone 1-800-750-2723 Ext 5051 or Email parts@usstove.com. Model Information Model Number Serial Number © 2022 United States Stove Company...
  • Page 24: Service Record

    Engineer Name: ____________________________________ Engineer Name: ____________________________________ License No.: ________________________________________ License No.: ________________________________________ Company: __________________________________________ Company: __________________________________________ Telephone No.: _____________________________________ Telephone No.: _____________________________________ Stove Inspected: Chimney Swept: Stove Inspected: Chimney Swept: Items Replaced: ____________________________________ Items Replaced: ____________________________________ © 2022 United States Stove Company...
  • Page 25 NOTES © 2022 United States Stove Company...

Table of Contents