Download Print this page

Christie DS Series User Manual page 21

Hide thumbs Also See for DS Series:

Advertisement

3. Response code / Error code
(1) ACK reply: 06h
When the projector receives the Set, Increment, Decrement or Execute
command correctly, the projector changes the setting data for the specified
item by [Type], and it returns the code.
(2) NAK reply: 15h
When the projector cannot understand the received command, the projector
returns the error code.
In such a case, check the sending code and send the same command again.
(3) Error reply: 1Ch + 0000h
When the projector cannot execute the received command for any reasons,
the projector returns the error code.
In such a case, check the sending code and the setting status of the projector.
(4) Data reply: 1Dh + xxxxh
When the projector receives the GET command correctly, the projector returns
the response code and 2 bytes of data.
NOTE • For connecting the projector to your devices, read the manual for
each devices, and connect them correctly with suitable cables.
• Operation cannot be guaranteed when the projector receives an undefined
command or data.
• Provide an interval of at least 40ms between the response code and any other
code.
• The projector outputs test data when the power supply is switched ON, and
when the light source is lit. Ignore this data.
• Commands are not accepted during warm-up.
• When the data length is greater than indicated by the data length code, the
projector ignore the excess data code. Conversely when the data length is
shorter than indicated by the data length code, the projector returns the error
code to the computer.
LWU1200-DS
User's Manual - Technical
RS-232C Communication
("h" shows hexadecimal)
19
020-001894-01 Rev. 1 (01-2021)
LIT MAN USR LWU1200-DS TECH

Advertisement

loading

This manual is also suitable for:

Lwu1200-ds