Persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge
can use the stove if they have been given supervision or instruction concerning use of the stove in a
safe way and understand the hazards involved.
The installation of the stove must be in accordance with legislation and regulations in the region or
state.
Any flammable objects must be kept at a safe distance from the product due to fire hazard in
accordance to the product manual.
Use only the fuel recommended by Aduro A/S. It is forbidden to use any liquid fuels and bioethanol
fluids for lighting/ rekindle charcoal or pellets.
Some of the surfaces on the product can get very hot (door, handle, glass, smoke outlet pipes, etc.).
Avoid therefore direct contact with these parts, without adequate protective clothing or suitable tools,
such as gloves with thermal protection.
Accumulated and unburned pellets in the brazier after "failed start-up" or alarms must be removed
before lighting again. Check that the cave is clean and positioned properly before lighting again.
We recommend that you install a smoke detector in the room where the Hybrid stove is installed.
If the smoke temperature exceeds 350 degrees, it can damage the gear motor.
It is recommended to let the stove burn empty for pellets and clean it before a still stand period
longer than 2 weeks – especially if the humidity is high.
A yearly service visit is obligatory and crucial to the functioning and safety of the stove. See section
6.4.
Aduro A/S declines all responsibility for any damage which may be caused, directly or indirectly, to persons,
animals, or objects as due to non-compliance with any provision specified in the manual, especially warnings
regarding installation, use, and maintenance of the stove.
The responsibility for improper use of the product is entirely borne by the user and relieves the manufacturer
from any civil and criminal liability. Tampering or unauthorized replacement with non-original spare parts
could be hazardous for the operator's safety and relieves the company from any civil and criminal liability.

1.3 Technical data

Aduro H1 & H3 LUX
Nominal power
Heats
Flue outlet
Fresh air supply
Measurements (HxWxD)
Height exhaust branch above floor level
Distance from centre of exhaust branch to rear
edge of stove
Weight
Material
Fuel
Max wood length
Convection stove
Primary, secondary, and tertiary air supply
Air-wash system
Data
7.0 kW wood / 6.8 kW pellets
20-140 m
/ 2-9 kW. Wood 3-9 kW / Pellets 2-7 kW
2
Ø15 cm top/rear
Ø7.8 cm external
120 x 50 x 50.8 cm
117 cm
25 cm
135 kg
Steel
Wood and pellets Ø6 mm, max length 40 mm. Pellets
in ENplus A1 quality.