Control Panel
Scrub Deck Pressure, Solution Flow Rate, and Chemical Flow Rate Adjustments
Each of the scrub settings (Regular, Heavy, and Extreme) affects the scrub deck pressure and solution low rate.
These settings are adjustable The default values are shown in the tables below The scrub pressures are determined
by examining the amperage through the brush motors.
Scrub Pressure & Amperage Specifications Chart
Default Pressure
Scrub Mode
Regular Scrub
Heavy Scrub
Extreme Scrub
Default Solution Flow Rate Chart
Solution Flow Indicator
One bar gauge(#1)
Two bar gauge(#2)
Three bar gauge(#3)
Restoring the Scrub Pressures to Factory Default Settings
Use this procedure to restore all of the scrub deck pressure settings to their factory default values
1
Turn the key switch to the off position
2
While holding the Scrub On switch (I) depressed, turn the key switch to the on position
◦ The display will show "d" to indicate that the factory default scrub pressures have been
restored
3
Release the switch and turn the key switch to the off position
Regular Scrub Setting Adjustment
Use this procedure to adjust the scrub deck pressure and solution rate that are used for the Regular scrub mode
1
Turn the key switch to the off position
2
While holding the Scrub On (I) and Scrub Off (H) switches depressed, turn the
key switch to the on position
3
Continue to hold the both switches until the switch indicators turn green
4
Release both switches The scrub off indicator will turn red and the regular scrub
indicator will turn yellow Also:
• The LED display will show the level number of the current scrub pressure
setting
5
Pressing the Scrub On switch (I) will scroll through the 3 scrub pressure settings
6
Pressing Scrub Off switch (H) will save the pressure setting and move to solution rate setting
7
Solution Rate Setting: The Regular Scrub indicator (I1) will turn from yellow to green and the
Solution indicator will turn yellow
8
Press the Solution switch (B) to scroll through the 3 solution rate settings
23 - FORM NO. 56043162 - Focus II Large
Brush Motor
Indicator
Amperage
1 bar(#1)
16 AMPS
2 bars(#2)
24 AMPS
3 bars(#3)
38 AMPS
Flow Rate
0.3 g/m
0.6 g/m
0.9 g/m
I
H1
I1
H
I
H
I2