F u n c .
N a m e
C o d e
C027
[EO] terminal selection
(Pulse/PWM output)
C028
[AM] terminal selection
(Analog voltage output
0...10V)
Digital current monitor
C030
reference value
Output [11] active state
C031
Output [12] active state
C032
C036
Alarm relay active state
C038
Output mode of low current
detection
Low current detection level
C039
Output mode of overload
C040
warning
Overload warning level
C041
C241
Overload warning level, 2
motor
" C " F u n c t i o n
D e s c r i p t i o n
13 programmable functions:
00Output frequency (PWM)
01Output current (PWM)
02Output torque (PWM)
03Output frequency (Pulse train)
04Output voltage (PWM)
05Input power (PWM)
06Electronic thermal load ratio
(PWM)
07LAD frequency (PWM)
08Output current (Pulse train)
10Heat sink temperature (PWM)
12General output (PWM)
15Pulse train input monitor
16Option(PWM)
11 programmable functions:
00Output frequency
01Output current
02Output torque
04Output voltage
05Input power
06Electronic thermal load ratio
07LAD frequency
10Heat sink temperature
11Output torque (with code)
13General output
16Option
Current with digital current monitor
output at 1,440Hz
Range is 20%~200% of rated
current
Select logic conversion, two option
codes:
00normally open [NO]
01normally closed [NC]
Two option codes:
00During acceleration,
deceleration and constant speed
01During constant speed only
Set the level of low load detection,
range is 0.0 to 2.0*inverter rated
current
Two option codes:
00During accel., decel. and
constant speed
01During constant speed only
Sets the overload warning signal
level between 0% and 200% (from
0 to two time the rated current of
the inverter)
nd
Sets the overload warning signal
level between 0% and 200% (from
0 to two time the rated current of
the inverter)
69
D e f a u l ts
Run
Mode
I n i t i a l
Edit
d a ta
07
*
1
[LAD]
07
*
1
[LAD]
Rated current
*
00
1
*
00
1
*
01
1
*
1
01
INV rated
current
*
1
01
Rated current
x 1.15
Rated current
x 1.15
U n i ts
A
-
A
A
A