F u n c .
N a m e
C o d e
b130
Deceleration overvoltage
suppression enable
Decel. overvolt. suppress level
b131
b132
Decel. overvolt. suppress
const.
Decel. overvolt. suppress
b133
proportional gain
b134
Decel. overvolt. suppress
integral time
GS input mode
b145
(refer to chapter ver.3.1 in
instruction manual)
b146
Delay time of release
operation (Ver.3.1 or after)
b147
Special monitor display
cancellation (Ver.3.1 or after)
Special monitor display
b148
re-display time (Ver.3.1 or
after)
Display ex.operator connected
b150
b160
1st parameter of Dual Monitor
2nd parameter of Dual Monitor
b161
b163
Frequency set in monitoring
b164
Automatic return to the initial
display
" b " F u n c t i o n
D e s c r i p t i o n
00Disabled
01Enabled
02Enabled with accel.
DC bus voltage of suppression.
Range is:
200V class330 to 395
400V class660 to 790
Accel. rate when b130=02.
Set range: 0.10 to 30.00 s
Proportional gain when b130=01.
Range is: 0.00 to 5.00
Integration time when b130=01.
Range is: 0.00 to 150.0
Seven option codes:
00No trip (Hardware shutoff only)
01E37
02 E98/E99/-S--
03 E99/-S--
04 -S--
05 E99/-S--/-F**
06 -S--/-F**
(02 to 06:Ver. 3.1 or after)
Valid only when b145 = 05,
Range is 0.00 to 2.00 s.
Two option codes:
00Cancellation of special display is
invalid
01Cancellation of special display is
valid
Time to return to special display,
Range is 1 to 30 s.
When an external operator is
connected via RS-422 port, the
built-in display is locked and shows
only one "d" parameter configured
in:
d001 ~ d060
Set any two "d" parameters in b160
and b161, then they can be
monitored in d050. The two
parameters are switched by
up/down keys.
Set range: d001 ~ d030
Two option codes:
00Freq. set disabled
01Freq. set enabled
10 min. after the last key operation,
display returns to the initial
parameter set by b038. Two option
codes:
00Disable
01Enable
66
Run
D e f a u l ts
Mode
I n i t i a l
U n i ts
Edit
d a ta
*
1
00
380
*
1
V
/760
*
1
1.00
s
0.20
1.0
s
*
1
00
*
1
0.00
s
*
1
00
*
1
30
s
001
001
002
00
-
00
-