TROUBLESHOOTING

DANGER
Problem
Gas regulator
leakage.
Power indicator OFF
Torch will not pilot;
When trigger is
activated.
Power indicator ON,
Overheat indicator
ON.
Torch will not pilot,
when torch trigger is
activated.
Follow all safety precautions whenever diagnosing or servicing the
tool. Disconnect power supply before service.
Possible Cause
Gas regulator on.
Main input power cord does not
connect to power distribution
net.
ON/OFF switch in OFF position.
Actual input voltage does not
correspond to voltage of unit.
Faulty components in unit.
Gas pressure too low.
Air flow blocked.
Fan blocked.
Unit is overheated.
Faulty components in unit.
Faulty parts in torch.
Gas pressure too high or too
low.
Faulty components in unit.
Remedy
Reset the regulator to 0 PSI and re-
adjust it to 65 PSI (4.5 bar).
Connect the power cord.
Turn switch to ON position.
Verify that the input line voltage is
correct.
Return for repair or have qualified
technician repair machine.
Adjust the pressure to 65 PSI/4.5 bar.
Check for blocked air flow around the
unit and correct condition.
Check for blocked status and correct
condition.
Keep the machine plugged in and
turned on for five minutes. This will
allow the fan to run and cool the
machine.
Return for repair or have qualified
technician repair machine.
Check torch parts, replace as needed.
Adjust pressure to proper setting value.
Return for repair or have qualified
technician repair machine.