Disabling/enabling the monitor function
This module register is bit-coded. These bits can be used to disable/enable indi-
vidual monitor functions. Keys are also mapped to flags with the monitor function
being disabled.
Property
Values
Value after reset
Description of the bits
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Description
0 ... 255
255
[R] key
0 =
[R] key has no monitor function
1 =
[R] key has monitor function
Displaying the flag state
[R] and [I/O] keys without monitor function Dis-
0 =
play flag state
1 =
[R] and [I/O] keys with monitor function Display
flag state
Displaying the output state
0 =
[I/O] key without monitor function Display out-
put state
1 =
[I/O] key with monitor function Display output
state
Displaying the input state
0 =
[I/O] key without monitor function Display input
state
1 =
[I/O] key with monitor function Display input
state
Changing register contents
0 =
[=] key without monitor function Change regis-
ter contents
1 =
[=] key with monitor function Change register
contents
Changing the flag state
0 =
[=] key without monitor function Change flag
state
1 =
[=] key with monitor function Change flag state
Changing the output state
0 =
[=] key without monitor function Change output
state
1 =
[=] key with monitor function Change output
state