Download Print this page

Fimco LG-55-3PT-12V Owner's Manual page 3

55 gallon 3 point sprayer & 7-nozzle boom assembly

Advertisement

After use, drain the tank and store or dispose of chemical properly.
Fill the sprayer half way with clean water. Start the pump and allow
the water to pump through the entire plumbing system and nozzles.
Drain and then refill half full, add the recommended amount of a
good quality tank cleaner, such as FIMCO Tank Neutralizer and
Cleaner. (If no tank cleaner is available, you may substitute dish
soap for this step, about 1-2 oz. per gallon). Turn pump on and
circulate through system for 15 minutes and then spray out through
boom and handgun nozzles. Refill sprayer half way with clean water
and repeat. Follow the chemical manufacturer's disposal instructions
of all wash or rinsing water.
If boom or handgun nozzles need cleaning, remove them from the
sprayer and soak in warm soapy water. Clean with a soft bristled
brush or toothpick if necessary. Never use a metal object. Even the
slightest damage can change the flow rate and spray distribution.
Water rinse and dry the tips before storing.
WARNING:
Some chemicals will damage the pump valves if
allowed to soak untreated for a length of time! ALWAYS flush
the pump as instructed after each use. DO NOT allow chemicals
to sit in the pump for extended times of idleness. Follow the
chemical manufacturer's instructions on disposal of all waste
water from the sprayer.
Winter Storage
Prepare the sprayer for end-of-season storage by running RV
antifreeze through the system. This will keep internal parts lubricated,
protect against corrosion and keep the unit from freezing. Note: RV
antifreeze is non-toxic and biodegradable and generally safer for the
environment than automotive antifreeze.
Before storing your sprayer for winter or long term storage,
thoroughly clean and drain it as much as possible. Then pour enough
pink RV antifreeze into the tank so that when the pump is turned on
you can pump the antifreeze throughout the entire plumbing system,
including the bypass. Make sure to operate the boom and handgun
until you see pink fluid spraying from the nozzles. Leave any
remaining antifreeze in the tank. Before your next usage, rinse the
antifreeze from the sprayer with clean water.
'Directo Valve' - Manually Operated Control Valve
Corrosion Resistant Materials: Wetted Parts Polypropylene, 316SS and Polyethylene
Maximum Pressure = 150 p.s.i.
Large Capacity - 12.5 G.P.M. @ 5 p.s.i. Pressure Drop
3/4" NPT (F) Inlet Connection
1/2" NPT (F) Spray Line Connection
3/4" NPT (F) Continuous By-Pass Connection
Valves may be connected w/close nipples for
multiple section spray control
Fimco #
Mfg. Part #
5143316
AA6B
5168718
PK-AB6B-KIT
Description
Directo-Valve (AA6B)
Repair Kit, Items Marked * *
It is nearly impossible to drain all of the water from the sprayer and
any trapped water can freeze in cold weather and damage parts of
the sprayer. Pumping the antifreeze through the system will displace
the water and help prevent this damage.
Removing from storage: drain the antifreeze. Fill the tank with fresh
water and run through the system. Dispose of antifreeze and flush
water properly.
Strap Attachment to a "Flat" Buckle
The nylon straps are to be inserted in and out of the
slots in the buckle, as shown. Be sure the straps are
snug before tightening the hook bolts. In most cases, it
will be necessary to re-tighten the straps after filling the
tank with liquid.
* * Available only in Repair Kit
♦ ♦ Only Available in Complete Assembly
Strap/Buckle Detail
Page 3

Advertisement

loading

This manual is also suitable for:

5300845