Equipment Description ....TEK-Mate® Perc Leak Detector Applicable Directives ....73/23/EEC as amended by 93/68/EEC...
Page 3
TEK-Mate combines sophisticated technology with durability for an instrument with outstanding sensitivity that's Laboratory Accurate, Toolbox Tough™. The TEK-Mate was found to be a low-cost solution for checking Perchloroethylene leaks by the California Aire Resource Board (California Industrial Dry Cleaning Report, Feb 2006).
3. Press the control button to power on the TEK-Mate. 4. Wait for the TEK-Mate to warm up. All three LEDs will illuminate during warm up. When the High sensitivity LED starts flashing and a chirping sound is heard, the TEK-Mate is ready to find leaks.
Page 5
How To Install Or Change the Sensor A new TEK-Mate is shipped with its sensor packed separately. The sensor must be installed before use. This specialized sensor will operate for about 100 hours before it will need to be replaced.
4. When the TEK-Mate signals a leak, pull the probe away from the leak for a moment, then bring it back to pinpoint the location. If the leak is large, set the sensitivity switch to LOW, by quickly pressing the main control button, to make it easier to find the exact site of the leak.
Troubleshooting Except for the batteries and the sensor, the internal parts of the TEK-Mate Leak Detector are not user serviceable. If you experience a problem with your TEK-Mate, see the Troubleshooting Table below to determine how to remedy the problem. If you can not remedy the problem, take your TEK-Mate to your wholesaler for evaluation.
May be operated for a limited time in lower temperature environments. Replacement Parts and Accessories Replacement parts and accessories for your INFICON TEK-Mate Perc Leak Detector are available through the same dealer from whom you bought the instrument. Plastic storage case ....705-401-P2 Replacement sensor.
Warranty and Liability INFICON warrants your TEK-Mate Perc Leak Detector to be free from defects of materials or workmanship for two years from the date of purchase. INFICON does not warrant items that deteriorate under normal use, including power cells, sensors and filters. In addition, INFICON does not warrant any instrument that has been subjected to misuse, negligence, or accident, or has been repaired or altered by anyone other than INFICON.
Page 12
TWO TECHNOLOGY PLACE EAST SYRACUSE, NY 13057-9714 USA Phone: +315.434.1100 Fax: +315.437.3803 E-Mail: service.tools@inficon.com www.inficon.com 074-477-P38A...