13.Reliability Test Conditions

13-1) Reliability Test Items
Table13-1 ReliabilityTest Items
No.
High temperature storage test
1
(Non operating test)
Low temperature storage test
2
(Non operating test)
High temperature and high humidity
3
operating test
High temperature operating test
4
Low temperature operating test
5
Thermal Shock test
6
(Non operating test)
Electro static discharge test
7
(Non operating test)
(Note) Ta = Ambient temperature
Tp = Panel surface temperature
Result Evaluation Criteria
Under the display quality test conditions with normal operation state, these shall be no change which may
affect practical display function.
(*)normal operation state:Temperature:15~35℃,Humidity:45~75%, Atmospheric pressure:86~106kpa)
13-2) Panel surface stress spesification
Panel surface stress spesification has been defined as a parameter "Force of stress [N]" without no picture failer.
Load testing: Minimum 120[N]
Test condition )
Test stracture
Press point
Press Jig
Press speed
Support
Press time
 ©Copyright 2017 SHARP All rights reserved
SPEC No.
Test Item
:LCD panel with polarizer
:Center of LCD panel
:φ10mm column
:1mm/minute
:fixed on stage
:5 seconds after achivement of the press strength,then reless it.
MODEL No.
LD-29608A
LS013B7DH01
Condition
Ta=80℃
Ta=-30℃
Tp=40℃/95%RH
( No condensation )
Tp=70℃
Tp=-20℃
Ta=-30℃ (1h)~+80 ℃ (1h) / 5 cycle
±200V、200pF(0Ω) each terminal: 1 time
(contact mode )
PAGE
Remark
240h
240h
240h
240h
240h
38