12. Reliability Test Conditions
12-1) Reliability test items
Table12-1
High temperature storage test
1
Low temperature storage test
2
High temperature and high humidity
3
operating test
High temperature operating test
4
Low temperature operating test
5
Shock test
6
(Non operating test)
Electro static discharge test
7
[Remark] Ta = Ambient temperature, Tp = Panel temperature
(Evaluation method)
In the standard condition, there shall be no practical problems that may affect the display function.
12-2) Panel surface stress spesification
Panel surface stress spesification has been defined as a parameter "Force of stress [N]" without no picture failer.
Load testing: Minimum 120[N]
Test condition )
Test stracture
Press point
Press Jig
Press speed
Support
Press time
SPEC No.
Test Item
:LCD panel with UV protection film
:Center of LCD panel
:φ10mm column
:1mm/minute
:fixed on stage
:5 seconds after achivement of the press strength,then reless it.
MODEL No.
LCY-12T09303B
Test condition
Ta=80degrees Celsius
Ta=35degrees Celsius
Tp=40degrees Celsius/95%RH 240h
Tp=70degrees Celsius 240h
Tp=-20degrees Celsius 240h
Ta=-30degrees Celsius (1h)〜+80 degrees
Celsius (1h) / 5 cycle
±200V、200pF(0Ω) each terminai: 1 time
LS013B4DN02
Remark
240h
240h
PAGE
28