6. SPECIFICATION

Part Numbers
Electrical
Alternator input voltage range (Intelligent type)
Automatic activation D+
Absorption charge voltage
Float charge voltage
Charge current
Total current of load and charging
Maximum charging efficiency
Temperature compensation
Voltage compensation
Charge algorithm
Protection
Communication
Storage temperature
Operating temperature
Enclosure
Battery Connection
Protection category
Weight
Dimensions (h*w*d)
Standards
Emission
PMDCS30
PMDCS60
12~16VDC
Default Setting: 14.4VDC
Default Setting: 13.5VDC
<30A
<30A
Default Setting: -3mV/°C/cell
Premium II Multi-Stage
• Battery charger over temperature
• Over load
• Short circuit
RS485, RJ45 connector
-40°C ~70°C
-40°C ~70°C
Cable with connector
181*148*52mm
ECE 10R-06, EN61000-6-1, EN61000-6-3
PMDCS30-20
Yes
<60A
<30A
<60A
<50A
96%
Yes
IP20
1.0kg