Verkada AC42 Install Manual page 8

Door controller
Table of Contents

Advertisement

Introduction
AC42 Technical Specifications
Power
Consumption
AC Power Input
Inputs
Readers
Relay Outputs
AUX Power
Dimensions
Weight
Operating
Temperature
Compliance
Connectivity
Included
Accessories
Mounting Options
8
60W maximum
100-240VAC
50/60Hz
1.5A maximum
2x REX dry inputs per door
1x DPI dry input per door
2x auxiliary dry inputs
1x reader port (Verkada/RS-485 or Wiegand) per door
Reader current consumption must be < 250mA per reader
Note: max of 4 readers can be powered simultaneously
1x wet or dry relay per door
Wet relay switch-selectable power:
● 12V operation 700mA max
● 24V operation 350mA max
Dry relay max pass-through power:
● 24VDC @ 2A (resistive load)
2x auxiliary dry relays
1x 12V @ 250mA
417 x 321 x 116.25mm
6.35kg
0°C - 50°C
FCC Part 15 Class A, ICES-3 Class A, CE, UKCA, RCM, VCCI, UL
294, CAN/ULC 60839-11-1, UL 62368-1, CSA C22.2 No. 62368-1,
IEC 62368-1, NDAA
Ethernet: 10/100Mbps RJ-45 for network connection
USB 2.0
Lock key and flat head screwdriver
Mounting plate and 4 wood screws
Verkada Inc. 406 E 3rd Ave, San Mateo, CA 94401
sales@verkada.com
5 - 90%
Humidity
All specifications are subject to change without notice