The technical data of the specific model are indicated on the label on the ventilator casing.

DESIGN AND OPERATING PRINCIPLE

The ventilator consists of an indoor unit with a decorative front panel, a cartridge, an air duct with a sound absorbing layer and an outer
ventilation hood.
The cartridge is a basic functioning part of the ventilator. The cartridge consists of the fans, the regenerator and two filters that ensure
rough air filtration and prevent ingress of dust and foreign objects into the heat exchanger and the fan.
The indoor assembly unit is equipped with automatic shutters that close during the ventilator standstill and prevent air backdraft.
TwinFresh Expert Duo
The
flows are directed in different directions.
The outer ventilation hood is used to prevent direct ingress of water and other objects to the ventilator.
A layer of sound-absorbing material for attenuation of noise generated
Construction consisting of fans, a regenerator and air filters.
Generates air flow and provides heat recovery.
Back part of the indoor unit
The unit includes a circuit control board and
basic controls located on the side part.
TwinFresh Expert
6
model has a set of air flow separators and an outer hood design that ensures that the exhaust and supply air
Prevents ingress of water and foreign objects into the ventilator.
Each ventilator model has a matching ventilation hood model.
Sound absorbing material
during the ventilator operation.
TwinFresh Expert cartridge
TwinFresh Expert Duo
TwinFresh Expert (Duo) R(M)W1-30/50/85/100(C1) V.2
VENTILATOR DESIGN
Outer ventilation hood
Back part of the indoor unit
The unit includes a circuit control board and basic controls located on the side part.
Front part of the indoor unit with a front panel
Fulfils the decorative function. The design enables to
shut off the air duct in case of an extended downtime of
the ventilator.
The front part of the TwinFresh Expert Duo unit is used
for air filtration.
Air ow separators
Designed for separation of
supply and exhaust air streams.
Air duct
Plastic air duct.
TwinFresh Expert Duo cartridge
Construction consisting of fans and regenerators.
Generates air flow and provides heat recovery.
Filters
Clean the air flowing through
the ventilator of dust and
foreign objects.
Prevent contamination of the
regenerator.
www.vents-us.com