In the event of losing the Wi-Fi password or the master ventilator password or in other cases, use the special Setup mode to restore access
to the ventilator functions.
To enter the special Setup mode, press and hold the
blinking of all the LED lights.
The ventilator will continue in this mode for 3 minutes and then automatically revert to the previous settings.
To exit the Setup mode immediately, press and hold the
the beep and shutdown of all the LED lights.
In this mode the following settings are available for the Master unit:
Wi-Fi network name: Setup mode.
Wi-Fi password: 11111111.
The unit password is ignored.
WHILE COMPLETING THE CONNECTION MAKE SURE THAT THE SLAVED VENTILATORS
AFTER CHANGING THE WI-FI PARAMETERS OF THE MASTER VENTILATOR REPEAT THE
To create a group of ventilators that are linked together as a Master and Slave, follow these steps:
Set the DIP switches on each ventilator to the position that corresponds to its role in the group (see "DIP switch position").
Then configure the Wi-Fi settings of the Master ventilator by following the instructions in the Vents Home mobile app.
Set the Master ventilator to the special mode as described above, and all LEDs on the ventilator casing will start flashing. Repeat the
steps with all the Slave units and wait for the beep when all the LED lights stop blinking on each Slave unit. Set the Master unit to the
normal operation mode. Press and hold the
Note: if the home router works in conjunction with several Wi-Fi access points requiring connection of ventilators to different access
points:
Connect the Master unit to the first Wi-Fi access point.
Complete the connection with the first group of Slave units.
Connect the Master unit to the second Wi-Fi access point.
Complete the connection with the second group of Slave units.
When the battery is low, the
following message on pressing the indicator icon. Low battery power may cause disruptions in the weekly schedule operation. Power off
the unit before replacing the battery. After replacing the battery reset the time and date.
The battery is located on the control board. To replace the battery, power off the ventilator, remove the front panel and the cover
protecting the control circuit board. Remove the battery and install the new one.
The battery type is : CR1220.
www.vents-us.com
Ventilation
ARE WITHIN WI-FI COVERAGE OF THE MASTER VENTILATOR
CONNECTING MASTER AND SLAVE VENTILATORS
Ventilation
REPLACEMENT OF THE BATTERY
Alarm
indicator on the unit casing will blink. The mobile app will also display the
SPECIAL SETUP MODE
button on the ventilator casing for 5 seconds until the beep and
Ventilation
button on the ventilator casing once again for 5 seconds until
CONNECTION STEPS!