Vents-us TwinFresh Expert RW1-50 V.2 User Manual page 10

Hide thumbs Also See for TwinFresh Expert RW1-50 V.2:
Table of Contents

Advertisement

3. Stick the delivered cardboard master plate on the indoor wall using a mounting tape. The large opening in the master plate must
be axially aligned with the air duct. For aligning the master plate with respect to the horizon line it is recommended to use a builder's
level. Then mark the fastening holes for installation of the supplied dowels and drill the holes to a required depth.
Route the power cable of the ventilator from the wall through the marked opening on the template.
4. Unlatch and detach the front part of the indoor unit from its back part.
5. Fix the back part of the indoor unit on the wall with the screws supplied with the mounting kit of the ventilator.
Remove the two retaining screws from the left transparent cover to enable access to the terminals.
6. Route the power cable as figured below and connect the
ventilator to power mains in compliance with the external wiring
diagram.
Fix the power cable and the signal cables with a cable clamp.
After completion of the electrical connection re-install the
transparent cover in site.
10
TwinFresh Expert (Duo) R(M)W1-30/50/85/100(C1) V.2
Hole marking for fan fastening
207
(8
/
'')
1
8
103,5
(4
1
/
'')
16
137
(5
3
/
'')
8
Ø 23 (Ø
15
/
'')
85
16
(3 3/8")
ATTENTION!
For the TwinFresh Expert RW1 prior to
mounting the front panel make sure
that the thermal actuator rod is in the
lowest position.
Blinking of the white led indicator
means that the thermal actuator is not
in the low position!
Cable clamp
Ø 5 (Ø
3
/
'')
16
4 holes
87,5
138
(3
7
/
'')
16
(5
7
/
'')
16
Ø 180
(Ø 7
/
'')
1
16
www.vents-us.com

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents