Vi.f) Additional Pump Settings - Tech Controllers EU-391 zPID User Manual

Table of Contents

Advertisement

EU-391 z PID

VI.f) Additional pump settings

Additional pump settings enable the user to select the type of additional pump : floor pump
/ DHW pump. The type of pump influences the range of temperature settings and protections
in case of alarms.
In the case of DHW pump, the user may change its activation temperature. It is the
threshold temperature at which the pump is enabled (the temperature measured by
additional sensor). The pump remains active until the temperature reaches the pre-set
value. Additionally, the user may adjust hysteresis of additional pump if DHW pump is
selected. In the case of floor pump, the user may preset the minimum temperature of the
sensor which is necessary for pump activation and the maximum temperature above which
the floor pump is disabled.
15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EU-391 zPID and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Eu-392 zpid

Table of Contents