Pentair OMNIFILTER F2000-B2B Installation And Operation Manual
Pentair OMNIFILTER F2000-B2B Installation And Operation Manual

Pentair OMNIFILTER F2000-B2B Installation And Operation Manual

Advertisement

Quick Links

OMNIFILTER
F2000-B2B FILTRATION SYSTEM
INSTALLATION AND OPERATION MANUAL
F2B1-RC
F2B2-RC
REDUCES
REDUCES
NSF/ANSI Standard 53
NSF/ANSI Standard 53
PFOA
PFOA
Certified to reduce cysts
Certified to reduce cysts
such as Crytosporidium
such as Crytosporidium
PFAS
PFAS
and Giardia by
and Giardia by
mechanical means.
mechanical means.
*Particulate reduction: 0.5 micron (Nominal)
*Particulate reduction: 0.5 micron (Nominal)
pentair.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OMNIFILTER F2000-B2B and is the answer not in the manual?

Questions and answers

Summary of Contents for Pentair OMNIFILTER F2000-B2B

  • Page 1 NSF/ANSI Standard 53 PFOA PFOA Certified to reduce cysts Certified to reduce cysts such as Crytosporidium such as Crytosporidium PFAS PFAS and Giardia by and Giardia by mechanical means. mechanical means. *Particulate reduction: 0.5 micron (Nominal) *Particulate reduction: 0.5 micron (Nominal) pentair.com...
  • Page 2: Specifications

    SPECIFICATIONS TOOLS AND MATERIALS REQUIRED • Safety glasses Temperature Range: ........40-100°F (4.4-37.8°C) • Adjustable wrench Pressure Range: ........40-100 psi (2.75-6.89 bar) • Tube cutter or utility knife Service Flow Rate @ 60 psi (4.1 bar): • Hand or electric drill (cordless recommended) Model: F2000-B2B ........0.6 gpm (2.27 L/min) •...
  • Page 3: Installation

    INSTALLATION NOTE: • For standard under-sink installation on 1/2" 14 NPS threads or 3/8" x 3/8" compression • Please read all instructions and precautions before installing and using your Filtration System • Numbered diagrams correspond with numbered steps 1. Installing the Water Supply Adapter The supply adapter fits 1/2"-14 NPS supply threads or 3/8"...
  • Page 4 INSTALLATION CONTINUED 3. Mounting the Faucet 7" (178mm) a. Apply 3-5 wraps of plumber's tape to faucet stem. Inlet b. Assemble faucet as shown in Figure 3. c. Screw quick connector onto threaded end of faucet stem. 16.25" d. Place a mark 5/8" from one end of the blue tubing. Wet the (413 mm) end of the 3/8"...
  • Page 5: Installation Continued

    INSTALLATION CONTINUED 7. Placing the System into Operation a. Slowly turn on the cold water supply. Ensure that the feed adapter valve is also open. b. Open faucet and flush filter for 10 minutes. Discard water. c. Check for leaks at all fittings before leaving installation. If leaks appear, see Troubleshooting.
  • Page 6: Troubleshooting

    O-rings. Place system into operation and check for leaks. If leaks persist, turn off the water supply and contact Technical Support at 1-800-279-9404. For replacement parts, contact your nearest Pentair distributor or call 800.279.9404 6 • F2000-B2B Filtration System Instruction Manual...
  • Page 7: Performance Data

    PERFORMANCE DATA F2000-B2B SYSTEM INSTALLED WITH F2B2-RC2 FILTER CARTRIDGE SET Important Notice: Read performance data and compare the capabilities of the system with your actual water treatment The system conforms to NSF/ANSI 42 and NSF/ANSI 53 for the specific requirements. It is recommended that the supply water be tested, performance claims verified and substantiated by test data.
  • Page 8 CUSTOMER CARE: 800.279.9404 | tech-support pentair.com | pentair.com ©2022 Pentair. All rights reserved. All indicated Pentair trademarks and logos are property of Pentair. Third party registered and unregistered trademarks and logos are the property of their respective owners. 4006792 Rev A AU22...