Table 4:ZE/ZF Chassis Central Controllers
Central
Name
Controller
AC Smart
Premium
AC Ez
Advanced
Control
Platform(ACP)
Standard
Advanced
Control
Platform (ACP)
Premium
Before specifying or placing an order, refer to the V-Net Network Solution Engineering Product Data Book and review the detailed technical data provided to fully understand the capabilities and limitations of
these devices.
Table 5:ZE/ZF Chassis Integration Solutions
Integration
Name
Solution
BACnet
®
PQNFB17C1
Gateway
LonWorks
®
PLNWKB100
Gateway
Before specifying or placing an order, refer to the V-Net Network Solution Engineering Product Data Book and review the detailed technical data provided to fully understand the capabilities and limitations of
these devices.
Devices
Model No.
per
Controller
PQCSW421E0A
128
PQCSZ250S0
32
PQCPA11A0E
256
PQCPB11A0E
256
Systems
Devices
per
Model No.
per
Comm
Controller
Bus
256
16
64
16
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
Systems
Devices
No. of
per Comm
per Comm
Comm
Bus
Bus
Bus Ports
16
128
1
16
256
1
64 (128
16
with PDI
Premium)
4
64 (128
16
with PDI
Premium)
No. of
Devices
Comm
per Comm
Power
Bus
Bus
Ports
64 (128
with PDI
4
24 VAC
Premium)
64
1
24 VAC
Binary
Signals
Power,
Description
Input/
Conn
Output
Provides scheduling,
autochangeover,
setback, remote controller
lock, setpoint,range limit, run
time limit, web access, email
alarm notification, visual
floorplan navigation,
2/2
24 VAC
peak/demand control,
software device interlocking,
PDI integration, and AC
Manager Plus integration
advanced functionality in
addition to basic unit control
and monitoring.
Provides for scheduling in
12 VDC,
addition to basic indoor unit
ODU
control and monitoring.
Provides for scheduling,
remote controller lock,
setpoint range limit, web
2/2
24 VAC
access, peak/demand
control, PDI integration,
and AC Manager Plus
integration advanced
functionality in addition to
10/4
24 VAC
basic unit control and
monitoring.
Binary
Signals
Description
Input/
Output
10/4
Allow integration of LG equipment
for control and monitoring by open
protocol BACnet
®
building automation and controls
systems.
2/2
and LonWorks
®