Table 2:Residential Energy Recovery Ventilator (ERV) Unit General Data
Temperature Exchange
Efficiency
(AHRI condition)
Enthalpy Exchange
Efficiency
(AHRI condition)
Wiring Connections
Dimensions
Power Input
Running Current
ERV
Air Flow Rate
Mode
External Static Pressure
Sound Pressure Level
Power Input
Running Current
Bypass
Air Flow Rate
Mode
External Static Pressure
Sound Pressure Level
Heat Exchanger
Supply Air Fan
Exhaust Air Fan
Duct Connecting
Connection Duct Diameter
Filters_1
Filters_2
Operation Range (Outdoor Temperature)
Model Name
Ventilation Capacity
Cooling
100% Air Flow
Cooling
75% Air Flow
Heating
100% Air Flow
Heating
75% Air Flow
Cooling
100% Air Flow
Cooling
75% Air Flow
Heating
100% Air Flow
Heating
75% Air Flow
Power Supply
Power Supply Cable(included Earth)
Power and Communication Cable(included Earth)
W x H x D
Net Weight
Air Flow Control Step
Rated
SH / H / L
Rated
SH / H / L
SH / H / L
SH / H / L
SH / H / L
SH / H / L
SH / H / L
Air Flow Control Step
Rated
SH / H / L
Rated
SH / H / L
SH / H / L
SH / H / L
SH / H / L
SH / H / L
SH / H / L
System Type
Element
Quantity
Fan Type
Motor Type
Motor Output
Quantity
Fan Type
Motor Type
Motor Output
Connecting Quantity
Outer Dia.
Quantity
Type
Dimensions
W x H x D
Quantity
Type
Dimensions
W x H x D
Min. ~ Max.
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
GENERAL DATA
ARV00903RA6, ARV01203RA6
ARV00903RA6
150
m³/h
ft3/min
90
%
65
%
69
%
61
%
65
%
61
%
66
%
58
%
61
V, Ø, Hz
208/230, 1, 60
No. x mm2 (AWG)
3C x 0.82 (18)
No. x mm2 (AWG)
-
mm
640 x 320 x 640
inch
25-3/16'' x 12-9/16'' x 25-3/16'' 25-3/16'' x 12-9/16'' x 25-3/16''
kg(lbs)
23.4(51.6)
-
SH / H / L
W
54.3 / 47.6 / 27.9
A
0.44 / 0.40 / 0.26
m3/h
150 / 150 / 80
ft3/min
90 / 90 / 47
Pa
100 / 70 / 50
in. H2O
0.4 / 0.28 / 0.2
dB(A)
28 / 26 / 21
-
SH / H / L
W
62.6 / 53.8 / 31.9
A
0.50 / 0.44 / 0.29
m3/h
150 / 150 / 80
ft3/min
90 / 90 / 47
Pa
100 / 70 / 50
in. H2O
0.4 / 0.28 / 0.2
dB(A)
28 / 26 / 21
-
Air to Air Cross Flow
Specially pocessed non-
-
fiammable paper
EA
1
-
Direct-Drive
-
BLDC
W
30
EA
1
-
Direct-Drive
-
BLDC
W
30
EA
4
Ø, mm(inch)
Ø 125 (4-23/25")
EA
2
-
Pre
mm
275 x 280 x 7
inch
10-13/16'' x 11'' x 1/4''
EA
1
-
MERV 13
mm
275 x 277 x 50
inch
10-13/16'' x 10-7/8'' x 1-15/16'' 10-13/16'' x 10-7/8'' x 1-15/16''
ºC DB(Fº DB)
-10~40 (14~104)
ARV01203RA6
200
120
62
65
58
61
55
61
52
58
208/230, 1, 60
3C x 0.82 (18)
-
640 x 320 x 640
23.4(51.6)
SH / H / L
79.2 / 71.4 / 30.5
0.62 / 0.56 / 0.28
200 / 200 / 100
120 / 120 / 60
100 / 70 / 50
0.4 / 0.28 / 0.2
30 / 28 / 22
SH / H / L
83.6 / 75.6 / 35.9
0.65 / 0.59 / 0.32
200 / 200 / 100
120 / 120 / 60
100 / 70 / 50
0.4 / 0.28 / 0.2
30 / 28 / 22
Air to Air Cross Flow
Specially pocessed non-
fiammable paper
1
Direct-Drive
BLDC
30
1
Direct-Drive
BLDC
30
4
Ø 125 (4-23/25")
2
Pre
275 x 280 x 7
10-13/16'' x 11'' x 1/4''
1
MERV 13
275 x 277 x 50
-10~40 (14~104)
7