Pressure Relief
Procedure
System pressure can cause the pump to cycle unex-
pectedly, which could result in serious injury from
splashing or moving parts.
1. Set START/STOP switch to STOP.
2. Push in SECURE DISABLE switch.
3. Open the back pressure regulator and all fluid drain
valves in the system, having a waste container
ready to catch drainage. Leave open until you are
ready to pressurize system again.
4. Check that pressure gauges on fluid supply and
return lines read zero. If gauges do not read zero,
determine cause and carefully relieve pressure by
VERY SLOWLY loosening a fitting. Clear obstruc-
tion before pressurizing system again.
Kit Parts
TDC Sensor Kit 15H877 includes the following
parts to replace the TDC sensor. Parts included in
the kit are marked with an asterisk, for example
(12*). Use all the new parts in the kit.
Ref.
No.
Part No. Description
12*
116719 SCREW, 8-32 hex washer head
25b* n/a
TDC SENSOR
33*
n/a
GASKET, circuit board
Parts designated n/a are not available separately.
2
Kit Installation
1. Jog the motor to bring the stand side lower to the
bottom of its stroke.
2. Relieve pressure, page 2.
3. Shut off electrical power to the unit.
4. Remove two screws (12) and the cover (32).
5. See F
. 1. Remove six screws (12), the circuit
IG
board cover (34), and the gasket (33).
6. Disconnect the transducer cable (25a) from J1 on
the circuit board (25c).
7. Disconnect the TDC cable (25b) from J2 on the cir-
cuit board (25c).
8. Disconnect the IS circuit field wire from J2 and J3.
See the Electrical Schematic in the E-Flo Plus
Repair-Parts manual 311594.
9. Remove four screws (12) and the circuit board
(25c).
10. Disconnect the TDC cable from J2 on the circuit
board.
11. Unscrew the TDC sensor (25b) from the gear hous-
ing.
Qty
12
1
1
Pressure Relief Procedure
311601A

Advertisement