DAB evoplus B 120/220.32 M Instruction For Installation And Maintenance

DAB evoplus B 120/220.32 M Instruction For Installation And Maintenance

Hide thumbs Also See for evoplus B 120/220.32 M:

Advertisement

V3.0
INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the evoplus B 120/220.32 M and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DAB evoplus B 120/220.32 M

  • Page 1 V3.0 INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE...
  • Page 2 B 120/220.32 M B 120/220.32 SAN M D 120/220.32 M B 40/220.40 M D 40/220.40 M B 60/220.40 M D 60/220.40 M ENGLISH page B 80/220.40 M D 80/220.40 M B 100/220.40 M D 100/220.40 M B 120/250.40 M B 120/250.40 SAN M D 120/250.40 M B 150/250.40 M B 150/250.40 SAN M...
  • Page 3 Torque: 19-20 ONLY FOR HEATING Figure 1: Assembly position Figure 2: Instructions for motor head assembly Figure 10: Control panel Figure 3: Installation on horizontal pipes...
  • Page 4 EVOPLUS Hmax [m] Qmax [m3/h] EVOPLUS Hmax [m] Qmax [m3/h] B 120/220.32 M - B 120/220.32 SAN M* 12.0 17.01 D 120/220.32 M 12.0 30.62 B 40/220.40 M 12.18 D 40/220.40 M 21.91 B 60/220.40 M 15.69 D 60/220.40 M 28.24 B 80/220.40 M 18.58...
  • Page 5 Table: Energy Efficiency Index - EEI EVOPLUS B 120/220.32 M 0,22 EVOPLUS D 120/220.32 M 0,22 EVOPLUS B 40/220.40 M 0,23 EVOPLUS D 40/220.40 M 0,23 EVOPLUS B 60/220.40 M 0,23 EVOPLUS D 60/220.40 M 0,23 EVOPLUS B 80/220.40 M 0,21 EVOPLUS D 80/220.40 M...
  • Page 8 ENGLISH INDEX INDEX OF FIGURES 1. Particular warnings ....................13 Figure 1: Assembly position ..................1A 2. Pumped liquids .......................13 Figure 2: Instructions for motor head assembly ............1A 3. Electromagnetic Compatibility (EMC) ..............13 Figure 3: Installation on horizontal pipes ...............1A 4. Management ......................13 Figure 4: Electrical connections (front) ................14 4.1 Storage ........................13 Figure 5: Electrical connections (rear) ................14...
  • Page 9: Installation

    ENGLISH 1. PARTICULAR WARNINGS 4.2 Transport Avoid subjecting the products to needless impacts and collisions. To lift and transport the Ensure that the product has not suffered any damage during transport circulator use lifting devices with the aid of the pallet supplied with it (if contemplated). or storage.
  • Page 10: Electrical Connections

    ENGLISH 5.3 Non-return valve Never insulate the electronic control device. If the system is equipped with a non-return valve, ensure that the minimum pressure of the circulator is always higher than the valve closing pressure. - In the case of maintenance, always use a set of new gaskets. 6.
  • Page 11 ENGLISH 6.1 Power supply connection With reference to Figure 7 the digital inputs available are: Input Terminal no. Type of contact Associated function EXT: If is activated from the control panel Clean contact (see par. 12 Page 11.0 of the EVOPLUS menu) it will be possible to command the switching on and off of the pump in re- mote mode.
  • Page 12 ENGLISH The MODBUS communication configuration parameters are available in the advanced With reference to Figure 9 the digital outputs available are: menu see Par.10). EVOPLUS circulators also have the possibility of communicating on Output Terminal no. Type of Associated function LON bus through external interface devices.
  • Page 13 ENGLISH As well as being at a high temperature and pressure, the fluid in the sys- - Primary circuits with high load losses tem may also be in the form of steam. DANGER OF SCALDING! - Domestic water recirculating systems with thermostatic valves on the rising col- It is dangerous to touch the circulator.
  • Page 14: Control Panel

    ENGLISH Regulation indicated for: 10 MENUS - Plants with variable flow (two-pipe heating EVOPLUS circulators offer 2 menus: user menu and advanced menu. plants), where a further reduction of the circu- The user menu is accessible from the Home Page by pressing and releasing the central lator performance is ensured depending on the “Menu”...
  • Page 15 ENGLISH Page 2.0 displays 3 icons which represent: The main settings of the system are graphically summed up Home Page on the Home Page. - central icon = setting currently selected The icon at top left indicates the type of regulation selected. - right icon = next setting The icon at centre top indicates the operating mode selected - left icon = previous setting...
  • Page 16: Factory Settings

    ENGLISH If the system finds any faults it records them permanently in the If a twin system is used (see Par. 6.3) on page 8.0 you can set Alarms Log Page 8.0 alarms log (up to a maximum of 15 alarms). For each recorded one of the 3 possible twin operation modes: Alternate every 24h: The 2 circulators alternate in reg- alarm a page composed of 3 parts is displayed: an alphanumer-...
  • Page 17: Types Of Alarm

    ENGLISH 12. TYPES OF ALARM 13. ERROR CONDITION AND RESET Alarm Code Alarm Symbol Alarm Description Display Description Reset indication e0 - e16; e21 Internal Error Internal error - Switch off system power. - Wait for the warning lights on the control panel Short Circuit e17 - e19 e0 –...
  • Page 18 ENGLISH - Switch off system power. Motor - Wait for the motor to cool down. excess tem- - Power the system again. perature f < 100 Hz ; Check that the PWM external signal is operating e57 ; e58 and connected as specified. f >...
  • Page 19 Tel. +7 495 122 0035 Tel. +49 2161 47 388 0 Fax +7 495 122 0036 Fax +49 2161 47 388 36 DAB PUMPS DE MÉXICO, S.A. DE C.V. DAB PUMPS (QINGDAO) CO. LTD. DAB PUMPS HUNGARY KFT. Av Amsterdam 101 Local 4 No.40 Kaituo Road, Qingdao Economic &...

This manual is also suitable for:

Evoplus b 120/220.32 san mEvoplus d 120/220.32 mEvoplus b 40/220.40 mEvoplus b 60/220.40 mEvoplus b 80/220.40 mEvoplus b 100/220.40 m ... Show all