Maintenance/repair
4.4.4

Cleaning and replacing the intake filter element

For the maintenance or replacement of the intake filter of a compressor unit based on the CG80 com-
pressor stage (third-party manufacturer), only the instructions from the manufacturer are applicable.
NOTE
Intake filters from diverse manufacturers can be installed. Also observe the instructions from the manu-
facturer.
Loosen the star grip nuts (1) on the compressor
unit and then remove the cover (2).
Remove filter elements (3).
Clean filter elements (3) by lightly tapping or
replace if necessary.
NOTICE
INCORRECT FILTER CLEANING!
Do not clean filter elements with compressed air,
benzine or other liquids.
Only clean or replace the filter element accord-
ing to the instructions.
Assembly occurs in reverse order.
4.4.5

Check the safety valve

The safety valve (2) is usually installed on the dis-
charge silencer (1).
NOTE
The discharge silencers (1) supplied by GHH RAND
have an integrated safety valve (2).