Modulator Linearity Validation; Gui Settings (A) - Texas Instruments TRF3722EVM User Manual

Table of Contents

Advertisement

EVM Jumper Configuration
3.2

Modulator Linearity Validation

Validate modular linearity using the following steps:
1. Connect the J7 RFOUT SMA connector to a Spectrum analyzer.
2. Connect the baseband in-phase positive signal to SMA connector J6 and in-phase negative signal to
SMA connector J5. Connect positive quadrature signal to SMA connector J4 and negative quadrature
signal to SMA connector J3.
3. Connect a mini-USB cable from the computer to J8. This should turn ON the blue LED (D3).
4. Terminate any unused SMA connectors to 50-Ω load.
5. Connect 6-V power adaptor. This should turn ON the red LED (D1).
6. Launch the TRF3722 GUI.
7. As an example, this guide now considers an RF target frequency of 1986.56 MHz.
8. Set the GUI as shown in
6
TRF3722 EVM User's Guide
All manuals and user guides at all-guidesbox.com
Figure 6
and
Figure
7.
Figure 6. GUI Settings (a)
Copyright © 2014, Texas Instruments Incorporated
www.ti.com
SLOU385 – May 2014